To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

AVEVA™ Adapters

Showing 89

PI Adapter for MQTT should include MQTT broker

Having to deal with a MQTT broker between the data source and the PI Adapter adds a single point of failure to the data handling and weakens the data flow end-to-end. From the data source we can guarantee that the data will reach the MQTT broker, ...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

PI Adapter for EtherNet/IP

Develop a PI adapter to talk directly to Rockwell PLCs using EtherNet/IP without requiring an OPC UA server.
Guest about 2 years ago in AVEVA™ Adapters / New Connectivity 1 No status

Add AVEVA Adapters to the Enterprise Agreement

Before, one of the main attractions of the Enterprise Agreement (EA) was that you get unlimited access to all standard PI Interfaces and PI Connectors. However, now that AVEVA Adapters are the successors to PI Interfaces and PI Connectors, and sin...
Guest about 2 years ago in AVEVA™ Adapters / General 2 Declined

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI adapter for PI-to-PI

We need a new robust product to support data transfer between PI servers in separate domains (operational network --> business network). This product would need to support the following: Highly available remote management/deployment multiple in...
Guest over 1 year ago in AVEVA™ Adapters / New Connectivity 3 No status

PI Adapter High Availability Resilience

Problem Summary: The client failover service for PI adapter is not highly available. If the client failover service node is unavailable, then the PI adapter instances that it manages will lose failover functionality. This is further exacerbated if...
Guest over 1 year ago in AVEVA™ Adapters / General 1 No status

PI Adapter for OPC UA data conversion

As a PI System Administrator, I would like to be able to apply conversion factors to the data that is being gathered from our OPC UA server. This would allow us to get data in the format/units we'd like, without requiring extra tags and/or calcula...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

Enable Auto Discovery for PI Adapter for MQTT SparkplugB to always listen for Birth and Death messages

When utilizing the SparkplugB protocol for MQTT, it would be beneficial for the adapter to be always listening for birth and death messages from specific Edge of Network nodes. This way, the device can send a birth message to have itself added t...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 1 Tell us more

PI Adapter for Structured Data Files support for files with format: tag,timestamp,value

input file format is (where identifier is the tag/stream name): identifier, timestamp,value identifier, timestamp,value ...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files / General 1 Tell us more

Detect and monitor which OPC UA server the PI Adapter is connected to

When configuring a PI Adapter to leverage server-level redundancy, it is not currently possible to monitor which server instance the PI Adapter is connected to. Surfacing this information would allow server administrators to better monitor the hea...
Giulio Cattarin over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration