Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 622 of 622

displayname/localname for identifier that excludes namespace and data type

Example: OPC UA Server 'Name': 2.0:W-HVAC-AC-1-IO!Wtot Namespace: 2 Datatype: 0 Identifier: W-HVAC-AC-1-IO!Wtot OPC UA Server 'DisplayName': W-HVAC-AC-1-IO!Wtot OPC UA Adapter {Identifier} returns: 2.0:W-HVAC-AC-1-IO!Wtot Required stream name: W-H...
Glenn Moffett 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Enable Auto Discovery for PI Adapter for MQTT SparkplugB to always listen for Birth and Death messages

When utilizing the SparkplugB protocol for MQTT, it would be beneficial for the adapter to be always listening for birth and death messages from specific Edge of Network nodes. This way, the device can send a birth message to have itself added t...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 1 Tell us more

PI Adapter for EtherNet/IP

Develop a PI adapter to talk directly to Rockwell PLCs using EtherNet/IP without requiring an OPC UA server.
Guest over 2 years ago in AVEVA™ Adapters / New Connectivity 1 No status

Add AVEVA Adapters to the Enterprise Agreement

Before, one of the main attractions of the Enterprise Agreement (EA) was that you get unlimited access to all standard PI Interfaces and PI Connectors. However, now that AVEVA Adapters are the successors to PI Interfaces and PI Connectors, and sin...
Guest over 2 years ago in AVEVA™ Adapters / General 2 Declined

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI adapter for PI-to-PI

We need a new robust product to support data transfer between PI servers in separate domains (operational network --> business network). This product would need to support the following: Highly available remote management/deployment multiple in...
Guest over 1 year ago in AVEVA™ Adapters / New Connectivity 3 No status

More control on MQTT parameters on the AVEVA Adapter for MQTT

It would be nice to have more control on additional MQTT parameters for the AVEVA Adapter for MQTT. We are especially interested in having control on the QoS of the subscription. Setting this would give us more control in buffering, especially whe...
Guest 2 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Enable subscribe using wildcard for AVEVA Adapter for MQTT

It would be handy to have the PI Adapter for MQTT to be able to subscribe to a broker by using wildcards only. Right now, we need to specify each individual topics on the data selection rule, and this eventually comes as individual subscription as...
Guest 2 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Alert if ingress detected to be in a bad state

During 2 recent lighthouse projects, most recently with Kimball Electronics, the machine hosting the PI to ADH agent experienced a reboot due to patch installations. PI to ADH didn't properly restart (we'll investigate that separately) and, as suc...
Guest 10 months ago in PI to CONNECT / General 0 No status

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status