Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 52
100 VOTE

PI Adapter for OPC UA should be able to write outputs to the OPC UA Server

The PI Adapter should be able to create a data pipe listener on certain streams (unsolicited reads) that would trigger the writes back to the OPC UA Server. This is useful when providing set points to the equipment without the need of establishin...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 9 No status

Tableau Integration

Tighter product integration between Tableau and CONNECT data services. Note that CONNECT's APIs and data views can likely be used today to get data from Cds into Tableau.
Todd Brown 5 months ago in Data Platform Integration / New Integrations 1 No status

PI Adapter for OPC UA Array Support

As a PI System Administrator, I would like for the PI Adapter for OPC UA to support array data types from the OPC UA Server. A large amount of our data may be contained within arrays on our OPC UA Server, so we would not currently be able to colle...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 11 No status

PI Adapter for OPC UA should poll a series of items based on a trigger events

Same as the PI Interface for OPC DA feature with "Trigger Tags", the idea is to poll for updates on a series of item streams (tags) only when a certain item stream updates. The benefit of this is to create timestamp alignments between a series of...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Configure refresh interval start time

End-users of created virtual tables expect updates at specific times.Request would enable user to indicate when refresh should occur. For example, for daily refresh, indicating a time of 5am, so that end-users can query the updated table when they...
Glenn Moffett 3 months ago in Data Platform Integration / Virtual Tables & Shares 0 No status

Allow setting interpolation type in Adapters

We would like to be able to specify the interpolation type (linear vs step) when Adapter creates tags in Archive.
Guest 5 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Sampling/Publishing Interval parameters to be part of Data Selection description

When configuring the AVEVA Adapters in general, we would find more convenient to be able to define the ‘Sampling Interval’ and 'Publishing Interval' parameters inside the ‘Data Selection’ configuration per each data stream. For instance, when desc...
Christian Leroux over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Ability to set a "Rolling forward" date and time interval for the Power BI Connector

When the Power BI Connector gets data every XX minutes (30 minutes for ExxonMobil) for a period of time (2 years) from CONNECT DataViews, it adds millions of data points every XX (30) minutes. As such, it needs to move the START time of the query ...
Hege Dammen 5 months ago in Data Platform Integration / Power BI Connector 0 No status