To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Ability to Explicitly Define Cloud Data Type for Modbus TCP Data in Edge Data Store

Description / Business Context I am currently using AVEVA Edge Data Store with the Modbus TCP interface to collect data from industrial devices and forward it to CONNECT Data Services (CDS). For each Modbus data selection, the Modbus configuration...
Jean-Philippe Tricart 4 months ago in AVEVA™ Edge Data Store / Egress 0 No status

Store Images & Pictures into EDS

Ability to store images as time bound data into EDS, and send the images to OCS for longer term storage, viewing or modeling/analysis. Example scenario: a thermal camera takes a picture of a furnace, image stored locally, and then sent to OCS whe...
Guest almost 4 years ago in AVEVA™ Edge Data Store / Historian 2 Evaluating

Add another Archive Mode option for the PI Interface for UFL

There should be a way to configure the PI UFL interface to both discard duplicate events (same value at the same timestamp) and record multiple unique values for the same timestamp when these events come from multiple data files. For example, if...
Guest almost 4 years ago in AVEVA™ Adapters / General 0 Tell us more

PI Adapter High Availability Resilience

Problem Summary: The client failover service for PI adapter is not highly available. If the client failover service node is unavailable, then the PI adapter instances that it manages will lose failover functionality. This is further exacerbated if...
Guest about 3 years ago in AVEVA™ Adapters / General 2 No status

Enable TLS Configuration

As a customer I want HTTP and HTTPS support for Edge DS so that I can configure the appropriate level of transport security for my deployment
Guest almost 4 years ago in AVEVA™ Edge Data Store / General 2 Declined

Provide a streamlined way to rename streams and push the changes to the endpoint

The current process forces the user to modify the adapter configuration (DataSource for the prefix, DataSelection for the stream name) and the endpoint (PIDA, OCS). The adapter should support modifying directly the stream name and push those chang...
Guest almost 4 years ago in AVEVA™ Adapters / General 1 Future consideration

API to check Adapter buffer statistics

We can check buffer statistics with PI Buffer subsystem (pibufss -cfg, qs) and also with PI Connector/Relay, to verify whether Buffer is healthy, events in queue and etc.Adapter does not has any API to check this.
Ee Sheing Lee over 2 years ago in AVEVA™ Adapters / General 1 No status

Support Kerberos for adapters on Linux

Adapters are supported on Ubuntu, which also provides support for Kerberos (https://documentation.ubuntu.com/server/explanation/intro-to/kerberos/) Adding Kerberos support would increase the options for deploying adapters securely.
Mike Horrocks about 1 year ago in AVEVA™ Adapters / General 0 No status

EDS: OPC DA Connector

Ability for OPC DA connector to write data to Edge Data Store.
Guest almost 4 years ago in AVEVA™ Edge Data Store / Ingress 1 Declined

Expand PI Adapters to be installed on RedHat/CentOS

No description provided
Guest almost 4 years ago in AVEVA™ Adapters / General 4 Tell us more