To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

AVEVA™ Adapters

Showing 92

Specific debug log levels to troubleshoot specific issues

Similar to PI Interfaces (/DB for opcint), adapters should allow setting some additional debugging to troubleshoot specific issues, instead of only allowing a general LogLevel (Information, Trace, Warning, etc.) This would allow for more granular ...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Already exists

Can we please have an Adapter for the good old OPC DA, please ?

We still have OPC DA all over and it will take time for users to move over to UA Architecture unless one uses a wrapper or something to expose DA as UA (not sure if such a wrapper is available but other way is available). It would be great to have...
Guest over 2 years ago in AVEVA™ Adapters / New Connectivity 2 Declined

Allow PI Adapter for MQTT to log the raw json payload received from the broker

For troubleshooting, it can be very helpful to see the raw json payload that the adapter has received from the broker, rather than just the error response from the attempted parsing. It can be difficult to know why a parsing attempt has failed wit...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 2 Future consideration

PI Adapter for Structured Data Files support for UoMs

No description provided
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files / General 6 Tell us more

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Provide possibility to create stream metadata from table data

Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status information ...
Hans-Otto Weinhold about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 0 No status

Provide additional time formatting options for RDBMS Queries

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Include [optional] unit of measure in the data selection configuration.

Some data sources do not provide a unit of measure. It would be useful to be able to specify the unit of measure as part of the data configuration so that this information is provided to EDS/PI/ADH through the data flow.
Mike Horrocks 9 months ago in AVEVA™ Adapters / General 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Guest 9 months ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status