Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

AVEVA™ Adapters

Showing 98 of 644

API to check Adapter buffer statistics

We can check buffer statistics with PI Buffer subsystem (pibufss -cfg, qs) and also with PI Connector/Relay, to verify whether Buffer is healthy, events in queue and etc.Adapter does not has any API to check this.
Guest over 1 year ago in AVEVA™ Adapters / General 0 No status

Improve the message for performing on demand History Recovery on datacollectionmode: "CurrentWithBackfill" and "CurrentOnly"

Running edgecmd to perform HR on demand on the datasource: datacollectionmode of Non HistoryOnly. will return the following error: Operation Failed: NotFound (404)Unexpected error: Unexpected character encountered while parsing value: 0. path '", ...
Guest 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

BACnet Trend Log Object Collection.

BACnet TrendLog is an object that a controller may implement. Once configured, it’ll keep in memory a certain number of records for one particular point. It functions as a buffer in BACnet controllers to hold historical data in the event of discon...
Guest 10 months ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

scaling/scale data selection(s)

Simplify data management, setting scale at source
Glenn Moffett 10 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for OPC UA Discovery file attributes setting

At the moment the file generated consists 5 columns - nodeId,selected,name,streamId,dataFilterId. Columns "name" and "dataFilterId" are always with value "NONE". There is no option to set the attributes to include in the file.
Guest 11 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 7 No status

PI Interface DNP3 - unsolicited data listen only mode of operation requested

Is there an option in DNP3 driver (In fact at TCP level) to make it listen on a certain (usually 20000 for DNP3)? In era of IoT devices, most devices are sleeping devices, they wake up usually once a day and push data to DNP3 Master (PI), however ...
Guest almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 1 Tell us more

Allow MQTT adapter to parse timestamps in local time without specifying a timezone suffix to each timestamp

We would like the MQTT Adapter to be able to interpret timestamps in local time without needing to explicitly state the timezone or UTC offset in each timestamp, but for the adapter to always interpret the timestamps as being in a specific timezon...
Guest almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Stream-level debugging

As a PI System Administrator, I'd like to be able to trace values being received, and subsequently being sent by the Adapter, similar to PI Interfaces. Having the ability to trace/log timestamps and values for specific streams would greatly help ...
Guest almost 3 years ago in AVEVA™ Adapters / General 0 Future consideration

Allow default settings (eg. disable compression) for tags created by Adapters

We would like to be able to specify default settings for tags created by the adapters. This would include things such as disabling compression for tags on this adapter (without disabling it as the default for all new tags on the Data Archive). Thi...
Guest almost 3 years ago in AVEVA™ Adapters / General 0 No status