To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 570

PI Adapter for OPC UA should be able to write outputs to the OPC UA Server

The PI Adapter should be able to create a data pipe listener on certain streams (unsolicited reads) that would trigger the writes back to the OPC UA Server. This is useful when providing set points to the equipment without the need of establishin...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 7 No status

PI Adapter for OPC UA should be able to poll data from the OPC UA Server

Currently the PI Adapter for OPC UA only collects unsolicited advised data that is different from the previous value. We would need to see a polling feature to be able to: - Refresh slow moving streams with updates with the same value but differen...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 6 In development

Share Displays with External Partners

Ability to share a display of information (real-time & historical) with an external partner/company. Must support ability to secure and share specific displays with specific partners. It must be possible to share the display with an externa...
Guest about 2 years ago in Community Data Sharing / Display Sharing 1 No status

Allow remote configuration

Adapters are currently only listening on localhost (127.0.0.1) causing them to be only accessible locally. For docker containers, they can only be accessed from within the container or directly on the host (with the --network host switch which res...
Guest about 2 years ago in AVEVA™ Adapters / General 3 No status

Allow Adaptors to run in Docker

Allow Adaptors to run in Docker. This would ease the roll-out and management of adaptors. Also new Cisco switches now allow Docker instances on the switch, limiting the need for extra hardware.
Guest 6 months ago in AVEVA™ Adapters / General 2 Already exists

PI Adapter for OPC UA should poll a series of items based on a trigger events

Same as the PI Interface for OPC DA feature with "Trigger Tags", the idea is to poll for updates on a series of item streams (tags) only when a certain item stream updates. The benefit of this is to create timestamp alignments between a series of...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Support https instead of http only

No description provided
Guest about 2 years ago in AVEVA™ Adapters / General 1 No status

GUI Front End for UA Adapter

The OPC UA Adapter is a replacement for the OPC UA Connector and should thus provide similar functionality by providing a GUI.
Jonathan Brutt over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

Ability to create nested parent/child events using AVEVA Advanced Analytics

Support the ability to trigger events from data including parent/child relationships. Support mapping to Event Types that represent the S88 batch standard.
Todd Brown 5 months ago in Events 0 Needs review

Support security baselining

As a PI administrator, I need to baseline the security configuration of my PI System to ensure OSIsoft security best practices are followed. Below is a list of requested features. Baseline verification (read-only) for PI Data Archive: - PI Data ...