To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Configure refresh interval start time

End-users of created virtual tables expect updates at specific times.Request would enable user to indicate when refresh should occur. For example, for daily refresh, indicating a time of 5am, so that end-users can query the updated table when they...
Glenn Moffett about 1 year ago in Data Platform Integration / Virtual Tables & Shares 0 No status

Support of complex streams with PI Adapter for RDBMS with free attribute selection

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 2 Planned

CONNECT Integration with Grafana

Provide an integration with Grafana so that OCS data can be easily included alongside data from other sources in a simple-to-configure, but powerful visualization tool
Guest about 4 years ago in Data Platform Integration / New Integrations 1 No status

OPC UA Adapter: support Namespace index change after OPC UA Server restart

AVEVA adapter for OPC UA should support changes in the Namespace index that can happen after an OPC UA Server service restart. Currently, if the Namespace index of the source signals change, the adapter stops receiving data for every point in that...
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

EdgeCmd "add" data selection with CSV

At the moment the EdgeCmd data selection with a file path is limited to get and set. This means that to perform an update the data selection needs to be exported, modified, and the imported. It would be a great time saver to be able to provide a s...
Mike Horrocks about 1 year ago in AVEVA™ Adapters / General 0 Future consideration

Support URN in addition for URI for OPC UA Server redundancy

As stated in the documentation "Some OPC UA servers use URNs instead of URLs, which is not currently supported by this adapter.", adding support for URNs would increase the servers the adapter is compatible with.
Mike Horrocks about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

PI Adapter High Availability Resilience

Problem Summary: The client failover service for PI adapter is not highly available. If the client failover service node is unavailable, then the PI adapter instances that it manages will lose failover functionality. This is further exacerbated if...
Guest about 3 years ago in AVEVA™ Adapters / General 2 No status

Include the "Include variables having historical data only" flag for the OPC UA Adapter

The OPC UA Connector has a feature that should also be included with the AVEVA Adapter for OPC UA : UserAccessLevel=HistoryRead - No real time data to subscribe for and only has historical data stored Please add this feature to the adapter.
Guest 10 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
Guest almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Allow session persistence to support true QoS 2 data collection and backfill of events after a data source disconnection

It appears that regarding Session Persistence (persistent vs clean session), the Adapter hardcodes setting the Clean Session Flag for the generic data source (Sparkplug doesn’t QoS 2 nor session persistence) to true. This should be a user-defined ...
Daniel Lopez 5 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status