To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

All ideas

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

View security rights of a role

I would like to be able to understand, view, and modify the security rights of a role from a single display. It would be great to be able to also go a level up and see what rights a client has and trace which role gives them that right.
Derek Endres over 2 years ago in General / Security 1 No status

Make the Status filter work for imported Assets in Asset Explorer

I know the concept of STATUS is not supported in PI AF and as such not supported in PI to CONNECT. There is no equivalent to push up :>). I realize Asset rules might not be commonly defined in CONNECT for imported Assets, and when the RULES for...
Hege Dammen over 1 year ago in Data Views / General 0 No status

Power BI Connector does not recognize if the name of an ADH Namespace got changed

Challenge: We have been unable to connect the Power BI connector to a namespace in AVEVA Data Hub to look at Data Views. There has been a change in the name of the namespace itself (Folder name in AVEVA Connect got changed). It was not possible to...
Guest almost 3 years ago in Data Platform Integration / Power BI Connector 0 No status

Issues with UI when many items in stream metadata - Scrollbar is missing

When there are many items in a list of stream metadata which we are browsing to set up a asset rule, the scroll bars are missing to browsw through the list of metadata. Solution: put a scroll bar into the UI so that I can browse through all items ...
Hans-Otto Weinhold almost 3 years ago in Assets / Asset Rules 0 No status

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold almost 3 years ago in AVEVA™ Edge Data Store / Ingress 0 Planned

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Provide additional time formatting options for RDBMS Queries

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

Pro-active notification if data collection stops

Challenge: In normal operation, there is no need to constantly check, if data collection is up and running and healthy. In some cases, data collection can stop for any particular reason, but there is right now no possibility to see this or receive...
Jeff Branfield almost 3 years ago in Software Management / Edge System Health & Status 0 No status

Allowing the MQTT adapter to set PI Point attributes during the creation process

we're interested in having the ability to configure the zero, span and some other points parameters during the creation of the PI points. currently when points are created. they're defaulting to zero=0 and span=100. while also displaying Boolean p...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status