Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 63 of 693

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI Adapter for OPC UA data conversion

As a PI System Administrator, I would like to be able to apply conversion factors to the data that is being gathered from our OPC UA server. This would allow us to get data in the format/units we'd like, without requiring extra tags and/or calcula...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

option to not collect quality

Quality is not supported by the OPC UA Server/always zero.
Glenn Moffett over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 4 In development

Store Images & Pictures into EDS

Ability to store images as time bound data into EDS, and send the images to OCS for longer term storage, viewing or modeling/analysis. Example scenario: a thermal camera takes a picture of a furnace, image stored locally, and then sent to OCS whe...
Guest about 3 years ago in AVEVA™ Edge Data Store / Historian 2 Evaluating

Detect and monitor which OPC UA server the PI Adapter is connected to

When configuring a PI Adapter to leverage server-level redundancy, it is not currently possible to monitor which server instance the PI Adapter is connected to. Surfacing this information would allow server administrators to better monitor the hea...
Giulio Cattarin over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

Enable TLS Configuration

As a customer I want HTTP and HTTPS support for Edge DS so that I can configure the appropriate level of transport security for my deployment
Guest about 3 years ago in AVEVA™ Edge Data Store / General 1 Declined

Support OPC UA ReverseConnect

Support ReverseConnect, allowing for the connection to be establish from the more secure area where the OPC Server reside to the least secure area where the OPC Client / Adapter resides. This is implemented in many other client tools and SDK such...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Add parameter "Max Monitored Items per Subscription"

The connector for OPC UA includes a parameter “Max Monitored Items per Subscription”, which is very helpful in managing UA servers which may have limits on the maximum items per subscription. This parameter needs to also be available in the adapters.
Guest 10 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration