To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 43 of 693

Enable Adapter for OPC UA to use the Pub/Sub method

Pub/Sub is proposed to be a more efficient and scalable method of transferring data using OPC UA. Allowing the adapter to access data in this way would increase the options for data collection, and allow the OPC UA adapter to be used in many more ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Ban Russian industries using PI

Call for AEVA to exit Russian market immediately of obvious reasons, cancel product license and prevent existing users from accessing application. It is confirmed that PI still actively used on Yamal LNG, Arctic LNG2, Sakhalin LNG sites.
Guest about 1 year ago in CONNECT to PI 0 No status

Improve the message for performing on demand History Recovery on datacollectionmode: "CurrentWithBackfill" and "CurrentOnly"

Running edgecmd to perform HR on demand on the datasource: datacollectionmode of Non HistoryOnly. will return the following error: Operation Failed: NotFound (404)Unexpected error: Unexpected character encountered while parsing value: 0. path '", ...
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

scaling/scale data selection(s)

Simplify data management, setting scale at source
Glenn Moffett over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for OPC UA Discovery file attributes setting

At the moment the file generated consists 5 columns - nodeId,selected,name,streamId,dataFilterId. Columns "name" and "dataFilterId" are always with value "NONE". There is no option to set the attributes to include in the file.
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 7 No status

When using debug mode level tracing in opc ua, can we get a dump of the client settings and data source settings in the log file that are being used so we know the context of that session?

it will tell us exactly the full context the adapter is operating in when it starts up and connects to the data source.
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Specific debug log levels to troubleshoot specific issues

Similar to PI Interfaces (/DB for opcint), adapters should allow setting some additional debugging to troubleshoot specific issues, instead of only allowing a general LogLevel (Information, Trace, Warning, etc.) This would allow for more granular ...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Already exists

Simplify the security configuration for OPC UA

The newer OPC UA protocols have stricter security standards, which is good, but that makes configuring connections more difficult, especially with regard to the need to put in tunneling and open ports. It should be easier to establish a secure con...
Guest 11 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Pro-active notification if data collection stops

Challenge: In normal operation, there is no need to constantly check, if data collection is up and running and healthy. In some cases, data collection can stop for any particular reason, but there is right now no possibility to see this or receive...