Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 67 of 693

Ability to set a "Rolling forward" date and time interval for the Power BI Connector

When the Power BI Connector gets data every XX minutes (30 minutes for ExxonMobil) for a period of time (2 years) from CONNECT DataViews, it adds millions of data points every XX (30) minutes. As such, it needs to move the START time of the query ...
Hege Dammen 5 months ago in Data Platform Integration / Power BI Connector 0 No status

Specify stream properties in a CONNECT to PI transfer

Include a way to select (or filter out) different properties of a stream used in a CONNECT to PI transfer so that we can control the PI tag/s created.
Guest 6 months ago in CONNECT to PI 0 No status

Adapter for OPC UA to support Global Discovery Server

Currently, to manage the OPC UA Server/Adapter certificate, we have to manually move the certificate or get the certificate trusted beforehand. This is expected for self signed Application certificate for both the Server and the Client (Adapter). ...
Guest 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Tell us more

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI Adapter for OPC UA data conversion

As a PI System Administrator, I would like to be able to apply conversion factors to the data that is being gathered from our OPC UA server. This would allow us to get data in the format/units we'd like, without requiring extra tags and/or calcula...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

OMF: Time Range / Events / Spans Support

Support the concept of time ranges / events EFs / spans as a pre-defined type in the OSIsoft Message Format (OMF) spec.
Guest about 3 years ago in Developer Resources / Open Message Format (OMF) 7 Tell us more

option to not collect quality

Quality is not supported by the OPC UA Server/always zero.
Glenn Moffett over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 4 In development

Detect and monitor which OPC UA server the PI Adapter is connected to

When configuring a PI Adapter to leverage server-level redundancy, it is not currently possible to monitor which server instance the PI Adapter is connected to. Surfacing this information would allow server administrators to better monitor the hea...
Giulio Cattarin over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration