To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 77 of 694

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

View PI Adapter log files via REST calls

We would like to be able to see the adapter log files via REST calls. Going to the machine itself to view is problematic because of remoting into the router and then going into the container to view. I think in a lot of containerized situations a ...
Guest about 3 years ago in AVEVA™ Adapters / General 3 Tell us more

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI Adapter for Structured Data Files support for files with format: tag,timestamp,value

input file format is (where identifier is the tag/stream name): identifier, timestamp,value identifier, timestamp,value ...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files / General 1 Tell us more

PI Adapter for OPC UA data conversion

As a PI System Administrator, I would like to be able to apply conversion factors to the data that is being gathered from our OPC UA server. This would allow us to get data in the format/units we'd like, without requiring extra tags and/or calcula...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

Add AVEVA Adapters to the Enterprise Agreement

Before, one of the main attractions of the Enterprise Agreement (EA) was that you get unlimited access to all standard PI Interfaces and PI Connectors. However, now that AVEVA Adapters are the successors to PI Interfaces and PI Connectors, and sin...
Guest about 3 years ago in AVEVA™ Adapters / General 2 Declined

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 4 In development

option to not collect quality

Quality is not supported by the OPC UA Server/always zero.
Glenn Moffett over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

PI Adapter High Availability Resilience

Problem Summary: The client failover service for PI adapter is not highly available. If the client failover service node is unavailable, then the PI adapter instances that it manages will lose failover functionality. This is further exacerbated if...
Guest over 2 years ago in AVEVA™ Adapters / General 1 No status

Detect and monitor which OPC UA server the PI Adapter is connected to

When configuring a PI Adapter to leverage server-level redundancy, it is not currently possible to monitor which server instance the PI Adapter is connected to. Surfacing this information would allow server administrators to better monitor the hea...
Giulio Cattarin over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration