To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Allow partitioning configuration for virtual tables

Databricks allows for specification of partitioning configuration on a deltatable. In some cases, this can improve query performance when querying the deltashare. It would be nice if on the virtual table, partitioning options were available which ...
Adam Fink 8 months ago in Data Platform Integration / Virtual Tables & Shares 0 No status

Configure refresh interval start time

End-users of created virtual tables expect updates at specific times.Request would enable user to indicate when refresh should occur. For example, for daily refresh, indicating a time of 5am, so that end-users can query the updated table when they...
Glenn Moffett about 1 year ago in Data Platform Integration / Virtual Tables & Shares 0 No status

CONNECT Integration with Grafana

Provide an integration with Grafana so that OCS data can be easily included alongside data from other sources in a simple-to-configure, but powerful visualization tool
Guest almost 4 years ago in Data Platform Integration / New Integrations 1 No status

Allow session persistence to support true QoS 2 data collection and backfill of events after a data source disconnection

It appears that regarding Session Persistence (persistent vs clean session), the Adapter hardcodes setting the Clean Session Flag for the generic data source (Sparkplug doesn’t QoS 2 nor session persistence) to true. This should be a user-defined ...
Daniel Lopez 5 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Granularity into Virtual Table status

It would be useful to have more details about what sub-status and/or step the Virtual Table is on beyond the current available states. This is especially useful for troubleshooting table status and what step it may be stuck on.
Miranda Hill 5 months ago in Data Platform Integration / Virtual Tables & Shares 0 No status

Ability to set a "Rolling forward" date and time interval for the Power BI Connector

When the Power BI Connector gets data every XX minutes (30 minutes for ExxonMobil) for a period of time (2 years) from CONNECT DataViews, it adds millions of data points every XX (30) minutes. As such, it needs to move the START time of the query ...
Hege Dammen about 1 year ago in Data Platform Integration / Power BI Connector 0 No status

Enable subscribe using wildcard for AVEVA Adapter for MQTT

It would be handy to have the PI Adapter for MQTT to be able to subscribe to a broker by using wildcards only. Right now, we need to specify each individual topics on the data selection rule, and this eventually comes as individual subscription as...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Integration with MS Fabric Shortcuts

Analog to DataBricks DeltaSharing, MS Fabric Shortcuts would expose virtual tables from CONNECT Data Services into MS Fabric. See https://learn.microsoft.com/en-us/fabric/onelake/onelake-shortcuts. The idea is exactly the same than for the DataBri...
Christian Leroux over 1 year ago in Data Platform Integration / Virtual Tables & Shares 0 No status

CONNECT Integration with Snowflake

Integration between CONNECT and Snowflake (a common cloud SaaS data lake solution).
Guest almost 4 years ago in Data Platform Integration / New Integrations 0 No status

Configurable Hostname/IP Identifier for OMF Health Egress

The health tags and AF structure is created with the following naming pattern by default: <machine hostname>.<adapter type> To support modern containerized deployment models, please consider adding a configurable field that allows cust...