Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 83 of 694

remote ingress to EDS

Enable remote access to EDS OMF endpoint to support deployments where Adapter/OMF application is installed on different host/network to EDS because architecture must fit in with tiered networks for critical asset security. For example remote sites...
Guest about 3 years ago in AVEVA™ Edge Data Store / Ingress 3 Future consideration

Adapter for OPC UA to support Global Discovery Server

Currently, to manage the OPC UA Server/Adapter certificate, we have to manually move the certificate or get the certificate trusted beforehand. This is expected for self signed Application certificate for both the Server and the Client (Adapter). ...
Guest 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Tell us more

Extract tokens step, edit an earlier rule without having to re-do all subsequent rules

Allow updates and changes to previously created token(s)
Glenn Moffett 6 months ago in Assets & Metadata Rules / Asset Rules 0 No status

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI Adapter for Structured Data Files support for files with format: tag,timestamp,value

input file format is (where identifier is the tag/stream name): identifier, timestamp,value identifier, timestamp,value ...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files / General 1 Tell us more

PI Adapter for MQTT should include MQTT broker

Having to deal with a MQTT broker between the data source and the PI Adapter adds a single point of failure to the data handling and weakens the data flow end-to-end. From the data source we can guarantee that the data will reach the MQTT broker, ...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

PI Adapter for OPC UA data conversion

As a PI System Administrator, I would like to be able to apply conversion factors to the data that is being gathered from our OPC UA server. This would allow us to get data in the format/units we'd like, without requiring extra tags and/or calcula...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

Enable Auto Discovery for PI Adapter for MQTT SparkplugB to always listen for Birth and Death messages

When utilizing the SparkplugB protocol for MQTT, it would be beneficial for the adapter to be always listening for birth and death messages from specific Edge of Network nodes. This way, the device can send a birth message to have itself added t...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 1 Tell us more

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 4 In development