Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 164 of 721

Tableau Integration

Tighter product integration between Tableau and CONNECT data services. Note that CONNECT's APIs and data views can likely be used today to get data from Cds into Tableau.
Todd Brown 8 months ago in Data Platform Integration / New Integrations 1 No status

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Guest 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Guest 4 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 15 Planned

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Guest 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Allow client-level failover on a per data source component level

Currently the client-level failover for Adapters occur on a per Adapter level. Which means that for instances where multiple data sources are configured, in some circumstances failover may result in an instance with a bad connection to a particula...
Guest 10 months ago in AVEVA™ Adapters / General 0 No status

Allow PI Adapter for MQTT (Generic) to process non-json payloads

Some MQTT devices do not send json payloads; for example, some devices send a single value as the payload for a specific topic. It would be beneficial for the adapter to be able to handle this rather than to convert these payloads into json befo...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 3 In development

Include the "Include variables having historical data only" flag for the OPC UA Adapter

The OPC UA Connector has a feature that should also be included with the AVEVA Adapter for OPC UA : UserAccessLevel=HistoryRead - No real time data to subscribe for and only has historical data stored Please add this feature to the adapter.
Guest 2 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Enable OmfEgress component to be configurable by instance (by component)

In our process we wish to send a different set of data to different PI environments. For instance we would like all data to egress to the PROD environment while only egress a subset of data to the DEV environment, in which we don't need all the da...
Guest over 3 years ago in AVEVA™ Adapters / General 7 Future consideration

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status