To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA Data Hub. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

PI Adapters

Showing 81 of 543

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold 10 months ago in PI Adapters / AVEVA Adapter for OPC UA 1 No Status

Detect and monitor which OPC UA server the PI Adapter is connected to

When configuring a PI Adapter to leverage server-level redundancy, it is not currently possible to monitor which server instance the PI Adapter is connected to. Surfacing this information would allow server administrators to better monitor the hea...
Giulio Cattarin about 1 year ago in PI Adapters / AVEVA Adapter for OPC UA 3 Future Consideration

Add another Archive Mode option for the PI Interface for UFL

There should be a way to configure the PI UFL interface to both discard duplicate events (same value at the same timestamp) and record multiple unique values for the same timestamp when these events come from multiple data files. For example, if...
Guest over 1 year ago in PI Adapters / General 0 Tell us more

Failover support for Adapter for Modbus TCP

This is a new idea for the failover functionality specific to the Adapter for Modbus TCP. Copied from the original idea (https://pisystem.feedback.aveva.com/ideas/PIADAPTERS-I-23): As a customer, I need to ensure that the primary instance of the a...
Jiyeon Hwang about 1 year ago in PI Adapters / AVEVA Adapter for Modbus TCP 1 Planned

Transformation and Scaling for OPC UA Adapter

Implement transformation and scaling for OPC UA adaptor the way it exists for PI OPC DA interface tags. The user can modify egressed tags and the data will be transformed / scaled when egressed.
Guest over 1 year ago in PI Adapters 1 Future Consideration

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Guest 5 months ago in PI Adapters / AVEVA Adapter for Modbus TCP 0 No Status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest 3 months ago in PI Adapters / AVEVA Adapter for Azure Event Hubs 0 No Status

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani 10 months ago in PI Adapters / AVEVA Adapter for OPC UA 0 No Status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest 3 months ago in PI Adapters / AVEVA Adapter for Modbus TCP 0 No Status

Allow restricting access to the Adapter to only allow configuration by specific users

We want to make sure that we have more control over who can update an Adapter. Is there a way to add a login or other restriction to only permit certain users to be able to modify Adapters, similar to how, with PI Connectors, only specific Windows...
Daniel Lopez 6 months ago in PI Adapters / General 1 No Status