Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 583

AF Attribute not recongized in ADH transfer configuration if PI point data reference config string contains a datatype

We encountered an issue with PI to ADH (using current version of the Agent 2.2) not recognizing AF Attributes with PI Point Data References which have the pointtype in the data reference configuration. So that means if there is a config string for...
Guest about 1 year ago in PI to CONNECT / General 0 No status

API Console request-timeout and paging support

Provide option to modify request-timeout setting and optionally return multiple pages to aid in querying datasets and learning about the API
Glenn Moffett almost 2 years ago in Developer Resources / AVEVA™ Data Hub Developer Tools 0 No status

Track activity for a client

Managing client and client credentials would be improved if activity information was made available. At the very least, "last seen" would help identify if clients are no longer being used. Additional information would be useful for auditing and se...
Mike Horrocks over 1 year ago in General / Health & Manageability 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Guest 8 months ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Create the possibility to organize streams in a folder structure.

Challenge: As a customer I use namespaces of ADH to separate data for different business units or sites located in specific regional locations (US, EMEA, ASIAPAC). But in the corresponding locations I need to have a possibility to organize data st...
Jeff Branfield over 1 year ago in Data Management & Storage / SDS Explorer 0 No status

Provide possibility to filter streams in a REST API call based on their origin

Challenge: A customer (industrial operator) is sharing data with an equipment vendor on a specific equipment through AVEVA Data Hub Communities. The equipment vendor reads data via REST API using a (python) script to process it for further data an...
Guest over 1 year ago in Community Data Sharing / General 0 No status

Performance Equation capability in Data Hub

When AVEVA products such as AVEVA Production Accounting use the performance equation capabilities of on-premise PI Server extensively, but when the same product tries to consume the data from the Data Hub for similar complex calculations or valida...
Jaibabu Yakkala over 1 year ago in General / Calculations 0 No status

For PI substitution events, update the stream property IsSubstituted

Scenario: PI event substitutions for the preceding two months must be supplied to a data warehouse for reporting purposes. Updating IsSubstituted stream property, would allow an application to query for stream events where values had been substitu...
Glenn Moffett almost 2 years ago in PI to CONNECT / General 0 Evaluating

Add filter panel to filter on stream metadata and stream type

As Community data sharing becomes more popular, it will be more important to be able to easily find Streams to share and for the tenant accessing Shared Streams to be able to find them and create Data Views. I would like to see a Filter panel in t...
John Marriott 9 months ago in General / Health & Manageability 0 No status