Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 167 of 711

Allow PI Adapter for MQTT (Generic) to process non-json payloads

Some MQTT devices do not send json payloads; for example, some devices send a single value as the payload for a specific topic. It would be beneficial for the adapter to be able to handle this rather than to convert these payloads into json befo...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 3 In development

Egress via AF SDK

Please add AF SDK Egress as an additional optional egress component. This would be very helpful for customers who are using the adapters, but keeping the PI Server on-premise. The adapters are relatively light-weight services; however, the “cost” ...
Guest 4 months ago in AVEVA™ Adapters / General 0 No status

Send only data that has changed.

When transferring data via satellite it is necessary to keep bandwidth usage to a bare minimum. Currently OMF must send all values regardless of whether they have changed or not. If it could send only the data parameters that have changed that wou...
Guest over 3 years ago in Developer Resources / Open Message Format (OMF) 6 Declined

Enable OmfEgress component to be configurable by instance (by component)

In our process we wish to send a different set of data to different PI environments. For instance we would like all data to egress to the PROD environment while only egress a subset of data to the DEV environment, in which we don't need all the da...
Guest over 3 years ago in AVEVA™ Adapters / General 7 Future consideration

Allow Definition of Point Attributes via OMF to PI Web API

When creating containers via OMF the PI Points are created with default Point Attributes - if these need to be changed it is a manual process to subsequently change the attributes appropriately. As OMF solutions can be easily deployed it would be ...
Guest over 3 years ago in Developer Resources / Open Message Format (OMF) 2 No status

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

The Adapter framework needs to be able to perform scaling on raw data

Many users want to use Adapters for the nre abilities they offer versus Interfaces: Support for containers, Linux, edge deployment, new failover and fault tolerance, integration with CONNECT Data Services, etc. HOWEVER, many sites use Interfaces t...
Daniel Lopez 5 months ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 1 Future consideration

Sampling/Publishing Interval parameters to be part of Data Selection description

When configuring the AVEVA Adapters in general, we would find more convenient to be able to define the ‘Sampling Interval’ and 'Publishing Interval' parameters inside the ‘Data Selection’ configuration per each data stream. For instance, when desc...
Christian Leroux over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Support outputs/write data from PI Adapters

No description provided
Guest over 3 years ago in AVEVA™ Adapters / General 4 No status

Allow setting interpolation type in Adapters

We would like to be able to specify the interpolation type (linear vs step) when Adapter creates tags in Archive.
Guest 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status