Skip to Main Content
CONNECT feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Allow default settings (eg. disable compression) for tags created by Adapters

We would like to be able to specify default settings for tags created by the adapters. This would include things such as disabling compression for tags on this adapter (without disabling it as the default for all new tags on the Data Archive). Thi...
Guest about 4 years ago in AVEVA™ Adapters / General 0 No status

Adapter for OPC UA to support Global Discovery Server

Currently, to manage the OPC UA Server/Adapter certificate, we have to manually move the certificate or get the certificate trusted beforehand. This is expected for self signed Application certificate for both the Server and the Client (Adapter). ...
Ee Sheing Lee about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Tell us more

Provide synced times for Manual Refresh of with Scheduled Refresh of virtual tables with Interpolated Mode

When one does a manual refresh of a virtual table that is set for interpolated data, no cues are given of the offset \ start index. As a consequence, if the user picks a start time or end time that is inconsistent with scheduled refresh start inde...
Brian Deslatte 7 months ago in Data Platform Integration / Virtual Tables & Shares 0 No status

Connect Data Services & Confluent Kafka Integration [bi-directional]

1/2 [CDS as a Producer] Ability to stream data from Connect Data Services to Confluent Kafka would allow us to harmonize data from multiple sources in realtime (Connect Data Services, with other relational databases, and/or ERP systems for example...
Ronald_Bechaalany about 1 year ago in Data Platform Integration / New Integrations 0 No status

Bulk API call should have the average and summarize the datapoints.

see attached.
Hege Dammen about 1 year ago in Data Platform Integration / New Integrations 0 No status

PI Adapter for GE e-terrahabitat/HabConnect

We need a new robust product to support data transfer between GE e-terrahabitat/HabConnect and PI. This product would need to support the following: Highly available remote management/deployment multiple instances on a single node (to support larg...
Guest about 3 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Support System States for the Adapter for Azure Event Hubs

The data passed through the Adapter for Azure Event Hubs can be very dynamic in its configuration. It would be useful to be able to send system states to indicate bad data, and possibly the nature of that bad data. In the same way that interfaces ...
Mike Horrocks over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 2 No status

metadata table describing virtual table

This enables- Verify data table is correct- Ensure data is used correctly based upon configuration - Precision – data type.List virtual table, name, columns, last updated, assets, metadata, properties and their types
Glenn Moffett over 1 year ago in Data Platform Integration / Virtual Tables & Shares 0 No status

multiple schema support

Several sites and projects use virtual tables. Multiple schemas would allow organization simply what table is for which site/project manage security at the schema level
Glenn Moffett over 1 year ago in Data Platform Integration / Virtual Tables & Shares 0 No status

Improve the message for performing on demand History Recovery on datacollectionmode: "CurrentWithBackfill" and "CurrentOnly"

Running edgecmd to perform HR on demand on the datasource: datacollectionmode of Non HistoryOnly. will return the following error: Operation Failed: NotFound (404)Unexpected error: Unexpected character encountered while parsing value: 0. path '", ...
Ee Sheing Lee about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status