Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 162 of 693

Allow PI Adapter for MQTT (Generic) to process non-json payloads

Some MQTT devices do not send json payloads; for example, some devices send a single value as the payload for a specific topic. It would be beneficial for the adapter to be able to handle this rather than to convert these payloads into json befo...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 3 In development

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 14 Planned

OPC UA Adapter: support Namespace index change after OPC UA Server restart

AVEVA adapter for OPC UA should support changes in the Namespace index that can happen after an OPC UA Server service restart. Currently, if the Namespace index of the source signals change, the adapter stops receiving data for every point in that...
Guest 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Adding PI to CONNECT Transfer replication behaviour based on Edit Mode Search

Problem: Currently, each asset and stream from the PI System must be added individually to the PI to CONNECT Transfer. If an organisation wants to replicate all assets in a specific category or under a root element of the PI Asset Hierarchy, every...
Marco Diepold 3 months ago in PI to CONNECT / General 0 No status

Enable OmfEgress component to be configurable by instance (by component)

In our process we wish to send a different set of data to different PI environments. For instance we would like all data to egress to the PROD environment while only egress a subset of data to the DEV environment, in which we don't need all the da...
Guest about 3 years ago in AVEVA™ Adapters / General 7 Future consideration

Allow setting interpolation type in Adapters

We would like to be able to specify the interpolation type (linear vs step) when Adapter creates tags in Archive.
Guest 5 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Support URN in addition for URI for OPC UA Server redundancy

As stated in the documentation "Some OPC UA servers use URNs instead of URLs, which is not currently supported by this adapter.", adding support for URNs would increase the servers the adapter is compatible with.
Mike Horrocks 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Add ability to uncheck or remove attributes from existing transfer

Transfers are initially added by searching and then selecting elements then attributes to add. When we want to edit the transfer, we are only able to remove entire elements, not by attributes. This became an issue when we later found that we had a...
Hege Dammen 9 months ago in PI to CONNECT / General 0 No status

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Support of Event Frame Annotations

Sometimes, annotations in Event Frames are stored (e.g. when acknowledging/commenting a notification in PI Vision). This information should get replicated to CONNECT data services and be made available through CONNECT visualization services. The o...
Hans-Otto Weinhold 4 months ago in PI to CONNECT / General 0 No status