Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 27 of 693

Conditional Data Egress for Edge Data Store

Scenario: In a remote monitoring scenario, Edge Data Store is collecting data through OPC UA or ModbusTCP with a certain sampling rate (assumingly 1s). For normal operations, EDS shall egress only an aggregated one minute value of all analogue str...
Guest over 1 year ago in AVEVA™ Edge Data Store / Egress 0 No status

Kerberos Authentication from EDS to PI

Submitting on behalf of a customer concerned about meeting stringent security requirements. Kerberos is a staple in their security architecture and the would very much like to incorporate it here.
Guest about 3 years ago in AVEVA™ Edge Data Store / Egress 0 Future consideration

Add a new diagnostic: the IO rate in bytes or megabytes

The current IO rate diagnostic is helpful, but it only shows events per second. For sites who need to manage their bandwidth and make decisions about how much to buy and support from remote sites, it's very important to be able to monitor exactly ...
Daniel Lopez over 1 year ago in AVEVA™ Edge Data Store / Egress 0 No status

Use EDS to download OCS and PI data for use as a local data cache for Data Science in tools like R-Studio and Jupyter Notebook

As a data scientist, I would like to set up types, streams, and query data from OCS to use locally on my desktop in data science languages (e.g. R, Python) and tools I use (R-Studio, Jupyter Notebook) so that I can rapidly try different numerical ...
Gregg Le Blanc about 3 years ago in AVEVA™ Edge Data Store / Analytics & Calculations 1 Tell us more

EDS: security/authentication mechanism

Customer wants to deploy EDS at machine level to collect data from PLCs which are directly connected to the machine which would imply a proper security / authentication mechanism for EDS
Guest about 3 years ago in AVEVA™ Edge Data Store / General 1 Tell us more

Data Retention configuration for EDS SDS

We have no information regarding data retention. This could be clarified. Data retention should be better configurable as of now, only the stream size can be configured just by estimation. Provide a sizing and calculation tool for Edge Data Store ...
Hans-Otto Weinhold over 1 year ago in AVEVA™ Edge Data Store / Historian 0 No status

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Edge Data Store / Ingress 0 Planned

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

EDS: Modbus Serial Connector

Ability for Modbus Serial connector to write data to Edge Data Store.
Guest about 3 years ago in AVEVA™ Edge Data Store / Ingress 1 Declined