Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 188 of 694

Clearly state that a Data message cannot include both a container ID and a type ID

Right now, the documentation: https://omf-docs.readthedocs.io/en/v1.0/Data_Messages.html Mentions that "For each object, either typeid or containerid must be specified". However, it does not clearly state that you CANNOT include both in a data m...
Guest about 3 years ago in Developer Resources / Open Message Format (OMF) 0 No status

accept relative time period as historical start time for transfer settings

Business requirement to re-transfer dataset due either to network or server related issue(s).
Glenn Moffett over 2 years ago in PI to CONNECT / General 1 No status

Better align AVEVA CONNECT data services Asset Type to AF template

Right now, PI to CONNECT agent creates empty asset types for the assets it creates.Additionally, if you connect multiple agents which have the same templates (or the same template names), these will all be created as empty asset types.If the Asset...
Rene Thomassen over 2 years ago in PI to CONNECT / General 2 No status

Data Retention configuration for EDS SDS

We have no information regarding data retention. This could be clarified. Data retention should be better configurable as of now, only the stream size can be configured just by estimation. Provide a sizing and calculation tool for Edge Data Store ...
Hans-Otto Weinhold almost 2 years ago in AVEVA™ Edge Data Store / Historian 0 No status

Provide alternative message to 'No value defined"

When querying AF Element Information certain values display: "No value defined." and customer reaction was that there was something not working correctly/error that needed to be investigated. Suggestion was to change text to either show the value ...
Glenn Moffett almost 2 years ago in PI to CONNECT / General 0 No status

API Console request-timeout and paging support

Provide option to modify request-timeout setting and optionally return multiple pages to aid in querying datasets and learning about the API
Glenn Moffett almost 3 years ago in Developer Resources / AVEVA™ Data Hub Developer Tools 0 No status

For PI substitution events, update the stream property IsSubstituted

Scenario: PI event substitutions for the preceding two months must be supplied to a data warehouse for reporting purposes. Updating IsSubstituted stream property, would allow an application to query for stream events where values had been substitu...
Glenn Moffett about 3 years ago in PI to CONNECT / General 0 Evaluating

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Edge Data Store / Ingress 0 Planned

Show all assets a stream is referenced on

When a stream is selected in the SDS explorer, include a tab in the stream information that lists all assets where that stream is referenced by a stream property. Include both the asset name (with link) and the stream property name. Streams may be...
Cynthia Bourne about 1 year ago in Data Management & Storage / SDS Explorer 0 No status

EDS: Modbus Serial Connector

Ability for Modbus Serial connector to write data to Edge Data Store.
Guest about 3 years ago in AVEVA™ Edge Data Store / Ingress 1 Declined