Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

AVEVA Adapter for OPC UA

Showing 41

displayname/localname for identifier that excludes namespace and data type

Example: OPC UA Server 'Name': 2.0:W-HVAC-AC-1-IO!Wtot Namespace: 2 Datatype: 0 Identifier: W-HVAC-AC-1-IO!Wtot OPC UA Server 'DisplayName': W-HVAC-AC-1-IO!Wtot OPC UA Adapter {Identifier} returns: 2.0:W-HVAC-AC-1-IO!Wtot Required stream name: W-H...
Glenn Moffett over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Enable Adapter for OPC UA to use the Pub/Sub method

Pub/Sub is proposed to be a more efficient and scalable method of transferring data using OPC UA. Allowing the adapter to access data in this way would increase the options for data collection, and allow the OPC UA adapter to be used in many more ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Add parameter "Max Monitored Items per Subscription"

The connector for OPC UA includes a parameter “Max Monitored Items per Subscription”, which is very helpful in managing UA servers which may have limits on the maximum items per subscription. This parameter needs to also be available in the adapters.
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Simplify the security configuration for OPC UA

The newer OPC UA protocols have stricter security standards, which is good, but that makes configuring connections more difficult, especially with regard to the need to put in tunneling and open ports. It should be easier to establish a secure con...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Improve the message for performing on demand History Recovery on datacollectionmode: "CurrentWithBackfill" and "CurrentOnly"

Running edgecmd to perform HR on demand on the datasource: datacollectionmode of Non HistoryOnly. will return the following error: Operation Failed: NotFound (404)Unexpected error: Unexpected character encountered while parsing value: 0. path '", ...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

scaling/scale data selection(s)

Simplify data management, setting scale at source
Glenn Moffett over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for OPC UA Discovery file attributes setting

At the moment the file generated consists 5 columns - nodeId,selected,name,streamId,dataFilterId. Columns "name" and "dataFilterId" are always with value "NONE". There is no option to set the attributes to include in the file.
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 7 No status

When using debug mode level tracing in opc ua, can we get a dump of the client settings and data source settings in the log file that are being used so we know the context of that session?

it will tell us exactly the full context the adapter is operating in when it starts up and connects to the data source.
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Specific debug log levels to troubleshoot specific issues

Similar to PI Interfaces (/DB for opcint), adapters should allow setting some additional debugging to troubleshoot specific issues, instead of only allowing a general LogLevel (Information, Trace, Warning, etc.) This would allow for more granular ...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Already exists