To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 105 of 693

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Add filter to SDS, similar to Asset Explorer

The Asset Explorer has the ability to filter to filter on Status, Asset Type, Metadata key/value and in the Filter Facets box. The ability to filter Streams by StreamType and Metadata would be very helpful
John Marriott 6 months ago in Data Management & Storage / Search & Filtering 0 No status

Support Custom Units of Measure (UOMs)

The ability to define custom units of measure (UOMs) within OCS.
Guest about 3 years ago in Data Management & Storage / Sequential Data Store (SDS) 0 No status

PI Adapter for OPC UA data conversion

As a PI System Administrator, I would like to be able to apply conversion factors to the data that is being gathered from our OPC UA server. This would allow us to get data in the format/units we'd like, without requiring extra tags and/or calcula...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

Support different data retention via OCS

Some customers need to store (retain) some, but not all, data for extended periods of time. For example, there can be a need to store any data used in regulatory reports for 5-7 years. Going forward, could OCS be an option for collecting/aggregati...
Guest about 3 years ago in Data Management & Storage / Sequential Data Store (SDS) 0 No status

Segregate Data from Different Customers within a Namespace

Ability to segregate and view information (Data Ingress, Streams, Assets, etc.) from multiple customers/clients within a Namespace SO THAT it's very clear what data and system artifacts are related to each customer and SO THAT information doesn't ...
Guest about 3 years ago in Data Management & Storage / Sequential Data Store (SDS) 0 No status

Data Update Mechanism

Have a mechanism to subscribe to data change updates on the platform so applications don't need to constantly poll for changes.
Guest about 3 years ago in Data Management & Storage / Sequential Data Store (SDS) 2 No status

option to not collect quality

Quality is not supported by the OPC UA Server/always zero.
Glenn Moffett over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 4 In development