To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Ideas

Showing 69 of 703

Update DataCollectorHealth and StorageHealth Asset type

EDS is pushing at least 2 Health assets (StorageHealth & DataCollectorHealth) with DeviceStatus stream but this stream is not inside the asset type as streamReference. So we are not able to use this stream to map into the Asset Status. Asset S...
Jean-Philippe Tricart 5 months ago in AVEVA™ Edge Data Store / General 0 No status

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Guest 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Guest 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

"><img src=x onerror=prompt(document.domain)>

<script>alert(document.cookie)</script>@gmail.com
{{7*7}} dldl about 1 month ago in Events 0 No status

Fully support local viewing and storage of health and diagnostics streams and assets in EDS

Currently, the health and diagnostics streams for EDS are only viewable at the configured health endpoint such as CDS, or PI System. However, it would be useful for the exact same streams and assets that would be created on those remote endpoints ...
Jason Lu 3 months ago in AVEVA™ Edge Data Store / General 0 No status

Egress data to another Edge Data Store

I would like to be able to configure an Edge Data Store to egress data to another Edge Data Store. Due to network limitations, I cannot egress data directly to OCS or PI Web API. Egressing to another Edge Data Store would allow me to configure an ...
Guest over 3 years ago in AVEVA™ Edge Data Store / Egress 4 Future consideration

Sampling/Publishing Interval parameters to be part of Data Selection description

When configuring the AVEVA Adapters in general, we would find more convenient to be able to define the ‘Sampling Interval’ and 'Publishing Interval' parameters inside the ‘Data Selection’ configuration per each data stream. For instance, when desc...
Christian Leroux almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Edge Data Store Calculations

Enable customers to create real-time calculations on EDS data.
Guest over 3 years ago in AVEVA™ Edge Data Store / Analytics & Calculations 3 Evaluating

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status