To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA Data Hub. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

AVEVA Adapter for OPC UA

Showing 20 of 544

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
Guest 9 months ago in PI Adapters / AVEVA Adapter for OPC UA 1 No Status

PI Adapter for OPC UA data conversion

As a PI System Administrator, I would like to be able to apply conversion factors to the data that is being gathered from our OPC UA server. This would allow us to get data in the format/units we'd like, without requiring extra tags and/or calcula...
Guest over 1 year ago in PI Adapters / AVEVA Adapter for OPC UA 2 No Status

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold 10 months ago in PI Adapters / AVEVA Adapter for OPC UA 1 No Status

Detect and monitor which OPC UA server the PI Adapter is connected to

When configuring a PI Adapter to leverage server-level redundancy, it is not currently possible to monitor which server instance the PI Adapter is connected to. Surfacing this information would allow server administrators to better monitor the hea...
Giulio Cattarin about 1 year ago in PI Adapters / AVEVA Adapter for OPC UA 3 Future Consideration

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani 11 months ago in PI Adapters / AVEVA Adapter for OPC UA 0 No Status

Support OPC UA ReverseConnect

Support ReverseConnect, allowing for the connection to be establish from the more secure area where the OPC Server reside to the least secure area where the OPC Client / Adapter resides. This is implemented in many other client tools and SDK su...
Guest over 1 year ago in PI Adapters / AVEVA Adapter for OPC UA 0 No Status

When using debug mode level tracing in opc ua, can we get a dump of the client settings and data source settings in the log file that are being used so we know the context of that session?

it will tell us exactly the full context the adapter is operating in when it starts up and connects to the data source.
Guest 9 months ago in PI Adapters / AVEVA Adapter for OPC UA 0 No Status

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold 10 months ago in PI Adapters / AVEVA Adapter for OPC UA 0 No Status

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
Guest 6 months ago in PI Adapters / AVEVA Adapter for OPC UA 0 No Status

Specific debug log levels to troubleshoot specific issues

Similar to PI Interfaces (/DB for opcint), adapters should allow setting some additional debugging to troubleshoot specific issues, instead of only allowing a general LogLevel (Information, Trace, Warning, etc.) This would allow for more granular ...
Guest over 1 year ago in PI Adapters / AVEVA Adapter for OPC UA 2 Already Exists