Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 59 of 694

Allow MQTT adapter to parse timestamps in local time without specifying a timezone suffix to each timestamp

We would like the MQTT Adapter to be able to interpret timestamps in local time without needing to explicitly state the timezone or UTC offset in each timestamp, but for the adapter to always interpret the timestamps as being in a specific timezon...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Ban Russian industries using PI

Call for AEVA to exit Russian market immediately of obvious reasons, cancel product license and prevent existing users from accessing application. It is confirmed that PI still actively used on Yamal LNG, Arctic LNG2, Sakhalin LNG sites.
Guest about 1 year ago in CONNECT to PI 0 No status

Improve the message for performing on demand History Recovery on datacollectionmode: "CurrentWithBackfill" and "CurrentOnly"

Running edgecmd to perform HR on demand on the datasource: datacollectionmode of Non HistoryOnly. will return the following error: Operation Failed: NotFound (404)Unexpected error: Unexpected character encountered while parsing value: 0. path '", ...
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

scaling/scale data selection(s)

Simplify data management, setting scale at source
Glenn Moffett over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for OPC UA Discovery file attributes setting

At the moment the file generated consists 5 columns - nodeId,selected,name,streamId,dataFilterId. Columns "name" and "dataFilterId" are always with value "NONE". There is no option to set the attributes to include in the file.
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 7 No status

Include information from Json body in the stream name created by the MQTT Adapter

As a system admin I would like to send mqtt messages from multiple devices to a single topic on an mqtt broker. Each message would contain data for the device along with a field to say which device the data has come from. Then I would like to use ...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Allow PI Adapter for MQTT to log the raw json payload received from the broker

For troubleshooting, it can be very helpful to see the raw json payload that the adapter has received from the broker, rather than just the error response from the attempted parsing. It can be difficult to know why a parsing attempt has failed wit...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 2 Future consideration

Allowing the MQTT adapter to set PI Point attributes during the creation process

we're interested in having the ability to configure the zero, span and some other points parameters during the creation of the PI points. currently when points are created. they're defaulting to zero=0 and span=100. while also displaying Boolean p...
Guest 9 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

When using debug mode level tracing in opc ua, can we get a dump of the client settings and data source settings in the log file that are being used so we know the context of that session?

it will tell us exactly the full context the adapter is operating in when it starts up and connects to the data source.
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Access a community shared data view from MS Power BI connector

The ability for data views to be shared into a Community and for shared data views to be accessible in the Power BI Connector. This would allow all tenants in a community to leverage the same curated data view when building Power BI reports.
Guest about 3 years ago in Data Platform Integration / Power BI Connector 0 No status