Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 71

PI Adapters should handle good NULL Values like PI Connectors and submit to the archive

A PI Connector reading a Null value in good quality send it to the Archive A PI Adapter skip the value, this gives in the archive a wrong picture. please enable the PI Adapter to submit also Null values with good quality to the archive like PI Con...
Guest 9 days ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Send notifications when new steams are added to the community

As a client at the receiving end of community-shared streams, it would be helpful to receive automated notifications whenever new streams are shared, to improve discoverability and engagement.
omar alomari 2 months ago in Community Data Sharing / Stream Sharing 1 No status

Enable AVEVA Adapter for OPC UA to work with OPC UA Servers that only allow Dynamic Addressing and Virtual Browsing

Some OPC UA Servers have the concept of Dynamic Namespace Addressing and Virtual Browsing. The UA Nodes do not exist in the OPC UA Address Space. Nodeids are created\added to the Address Space only when a Client makes a request for the NodeIds thr...
Guest 20 days ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Share Displays with External Partners

Ability to share a display of information (real-time & historical) with an external partner/company. Must support ability to secure and share specific displays with specific partners. It must be possible to share the display with an externa...
Guest over 3 years ago in Community Data Sharing / Display Sharing 1 No status

PI Adapter for OPC UA Array Support

As a PI System Administrator, I would like for the PI Adapter for OPC UA to support array data types from the OPC UA Server. A large amount of our data may be contained within arrays on our OPC UA Server, so we would not currently be able to colle...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 12 No status

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee about 2 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for OPC UA should poll a series of items based on a trigger events

Same as the PI Interface for OPC DA feature with "Trigger Tags", the idea is to poll for updates on a series of item streams (tags) only when a certain item stream updates. The benefit of this is to create timestamp alignments between a series of...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Automated discovery on a schedule

Enable Regular Discovery: While not continuous by default, discovery can be scripted or scheduled to run periodically for dynamic environments include this as a feature, so that automatic discovery and automatic addition of new discoveries can be ...
Guest about 1 month ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Sampling/Publishing Interval parameters to be part of Data Selection description

When configuring the AVEVA Adapters in general, we would find more convenient to be able to define the ‘Sampling Interval’ and 'Publishing Interval' parameters inside the ‘Data Selection’ configuration per each data stream. For instance, when desc...
Christian Leroux almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status