To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 8

Detect when a stream was added or removed from the community

Have the ability to see if new streams were added/removed from the community. The idea is to automate actions on the receiving end of the community by adding the new streams to any sort or analytic or visual once a stream is added.
Fabio Dani 9 months ago in Community Data Sharing / Stream Sharing 1 No status

Support for adding metadata and tags to streams shared via a community

Allow for metadata and tags to be added to community streams so that community data sharing can be used in the same manner as other OCS streams. The metadata and tags should be kept private from the community, but simply reference streams shared ...
Guest about 3 years ago in Community Data Sharing / Stream Sharing 0 No status

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Pro-active notification if data collection stops

Challenge: In normal operation, there is no need to constantly check, if data collection is up and running and healthy. In some cases, data collection can stop for any particular reason, but there is right now no possibility to see this or receive...
Jeff Branfield about 2 years ago in Software Management / Edge System Health & Status 0 No status

Add Counts to AVEVA Data Hub Edge Data Store & Adapters Status Display

Add count next to each of the status (filter) boxes and enable status sorting based on the count. This will enable an admin to get a general overview of the health of the EDS and adapter population
Brian Deslatte over 1 year ago in Software Management / Edge System Health & Status 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Select Streams to be shared from Assets

There are cases when one wants to share all the Streams associated with an Asset. However the user must return to the Sequential Data Store and try to find all the desired Streams, which can be very difficult. It would be much easier if the user c...
John Marriott almost 2 years ago in Community Data Sharing / Stream Sharing 0 No status