Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

AVEVA™ Adapters

Showing 112

PI Adapter High Availability Resilience

Problem Summary: The client failover service for PI adapter is not highly available. If the client failover service node is unavailable, then the PI adapter instances that it manages will lose failover functionality. This is further exacerbated if...
Guest about 2 years ago in AVEVA™ Adapters / General 1 No status

Detect and monitor which OPC UA server the PI Adapter is connected to

When configuring a PI Adapter to leverage server-level redundancy, it is not currently possible to monitor which server instance the PI Adapter is connected to. Surfacing this information would allow server administrators to better monitor the hea...
Giulio Cattarin over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

Add another Archive Mode option for the PI Interface for UFL

There should be a way to configure the PI UFL interface to both discard duplicate events (same value at the same timestamp) and record multiple unique values for the same timestamp when these events come from multiple data files. For example, if...
Guest about 3 years ago in AVEVA™ Adapters / General 0 Tell us more

Failover support for Adapter for Modbus TCP

This is a new idea for the failover functionality specific to the Adapter for Modbus TCP. Copied from the original idea (https://pisystem.feedback.aveva.com/ideas/PIADAPTERS-I-23): As a customer, I need to ensure that the primary instance of the a...
Jiyeon Hwang over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 1 Planned

Support of complex streams with PI Adapter for RDBMS with free attribute selection

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 2 Planned

Support OPC UA ReverseConnect

Support ReverseConnect, allowing for the connection to be establish from the more secure area where the OPC Server reside to the least secure area where the OPC Client / Adapter resides. This is implemented in many other client tools and SDK such...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

REST API data source

e.g.: weather forecast, 3rd party
Glenn Moffett almost 3 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Add parameter "Max Monitored Items per Subscription"

The connector for OPC UA includes a parameter “Max Monitored Items per Subscription”, which is very helpful in managing UA servers which may have limits on the maximum items per subscription. This parameter needs to also be available in the adapters.
Guest 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

PI Adapter for Apache Kafka

Create a PI Adapter that supports reading data from Apache Kafka. Please comment with any specific data, requirements, or use cases that this adapter would need to support!
Guest about 3 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Provide a streamlined way to rename streams and push the changes to the endpoint

The current process forces the user to modify the adapter configuration (DataSource for the prefix, DataSelection for the stream name) and the endpoint (PIDA, OCS). The adapter should support modifying directly the stream name and push those chang...
Guest about 3 years ago in AVEVA™ Adapters / General 1 Future consideration