To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

AVEVA™ Adapters

Enable AVEVA Adapter for OPC UA to detect unchanged source values beyond a configured interval and continue sending the last known value with refreshed timestamps until a new source event is received

This enhancement is required so the AVEVA Adapter for OPC UA can functionally match ABB 800xA / Vtrin RTDB historical behavior while preserving existing PI System and Asset Framework functionality. The customer would like this capability implement...
Guest 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adaptor for Perfmon

To move to next gen AVEVA tech, and perform a migration to Adaptors, critical monitoring with perfmon adaptor (Instead of Interface for PIPerfMon) would be ideal. Portability of using linux, docker etc. and having this data be available in AVEVA D...
Guest 4 months ago in AVEVA™ Adapters / New Connectivity 1 No status

Start/stop components to be retained on restart

Currently it is possible to stop a component for a running adapter. However, if the adapter is restarted the component will automatically start up. It would allow for extra control during commissioning, downtime, incidents, etc. to be able to disa...
Mike Horrocks 9 months ago in AVEVA™ Adapters / General 0 No status

Include buffering metrics in adapter health

In the OmfEgress component in adapter health the metrics are limited to DeviceStatus, and IO rate. Another key metric for this component is the buffering state. To keep it simple it would be useful to have the number of events in the buffer. This ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / General 1 No status

PI Adapter for OPC UA should poll a series of items based on a trigger events

Same as the PI Interface for OPC DA feature with "Trigger Tags", the idea is to poll for updates on a series of item streams (tags) only when a certain item stream updates. The benefit of this is to create timestamp alignments between a series of...
Guest almost 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Add a parameter to disable NTLM authentication

On the "Health endpoints parameters" page of the documentation of any AVEVA Adapter, it states that Negotiate (i.e. try Kerberos first and fall back to NTLM if that fails) will be used if a username/password pair and a clientId/clientSecret pair a...
Guest about 1 month ago in AVEVA™ Adapters / General 0 No status

Automatic Configuration Sync between failover adapters

When adapters in a failover group, any changes to configuration need to be manually synchronised between the adapters. Without automation, this could lead to misaligned configuration causing data collection issues.
Mike Horrocks 2 months ago in AVEVA™ Adapters / General 0 No status

Adapter for BACnet - defaultStreamIdPattern add ObjectName as possible parameter

Currently, for the Adapter for BACnet its [Data source parameters] defaultStreamIdPattern does not have an option to include the ObjectName in the defaultStreamIdPattern. It would be good to include this as a possible parameter for the defaultStre...
Guest 4 months ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Allow client-level failover on a per data source component level

Currently the client-level failover for Adapters occur on a per Adapter level. Which means that for instances where multiple data sources are configured, in some circumstances failover may result in an instance with a bad connection to a particula...
Guest over 1 year ago in AVEVA™ Adapters / General 1 No status

Native MQTT Publishing (Egress) to Support Unified Namespace (UNS) Architectures

Description & Use Case: As the manufacturing industry shifts toward Industry 4.0 and Unified Namespace (UNS) architectures, data must flow seamlessly between all systems in a publish/subscribe model. The AVEVA PI System is exceptional at inges...
Guest 5 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status