Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 603

Support PI-to-Data Hub Agent configuration tool when Proxy Server is activated

It seems that if there is a proxy Server active that PI-to-Data Hub Agent does not run in "interactive" mode. It just comes up with the error message "Please log in to AVEVA Data Hub via the default system browser. If the login fails, relaunch the...
Guest over 1 year ago in PI to CONNECT / General 0 No status

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold over 1 year ago in AVEVA™ Edge Data Store / Ingress 0 Planned

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Provide possibility to create stream metadata from table data

Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status information ...
Hans-Otto Weinhold over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 0 No status

Provide additional time formatting options for RDBMS Queries

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

Allow user to augment an asset without PI to Data Hub overwriting the change

As a PI to Data Hub user, I have data in Data Hub that is not fed by PI to Data Hub. I want to be able to manually edit an Asset (built by PI to Data Hub) to refer to my other streams so I can see all relevant information for my asset at once with...
Janelle Minich almost 2 years ago in PI to CONNECT / General 0 No status

Add Counts to AVEVA Data Hub Edge Data Store & Adapters Status Display

Add count next to each of the status (filter) boxes and enable status sorting based on the count. This will enable an admin to get a general overview of the health of the EDS and adapter population
Brian Deslatte 8 months ago in Software Management / Edge System Health & Status 0 No status

CONNECT Agent for AVEVA Plant SCADA (Citect)

AVEVA Plant SCADA 2020r2 and newer, has an OPC UA Server, so the AVEVA Adaptor for OPC UA can be used to send data to CONNECT data services (AVEVA Data Hub). However native connectivity like the PI-to-CONNECT Agent or the System Platform Connector...
John Marriott 8 months ago in AVEVA™ Adapters / New Connectivity 0 No status

Support of Enumeration mappings for existing Streams which hold status information as Integer values

Problem: Some data sources (like Modbus PLCs or some OPC UA Servers) expose Status/Enumeration Data (On/Off etc) as an integer number rather than the status itself. This number is then stored in AVEVA Data Hub but to be able to interpret and use ...
Jeff Branfield over 1 year ago in Data Management & Storage / Sequential Data Store (SDS) 0 No status

Pro-active notification if data collection stops

Challenge: In normal operation, there is no need to constantly check, if data collection is up and running and healthy. In some cases, data collection can stop for any particular reason, but there is right now no possibility to see this or receive...
Jeff Branfield over 1 year ago in Software Management / Edge System Health & Status 0 No status