To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

AVEVA™ Adapters

Showing 98

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Allowing the MQTT adapter to set PI Point attributes during the creation process

we're interested in having the ability to configure the zero, span and some other points parameters during the creation of the PI points. currently when points are created. they're defaulting to zero=0 and span=100. while also displaying Boolean p...
Guest about 2 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

option to not collect quality

Quality is not supported by the OPC UA Server/always zero.
Glenn Moffett 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Transformation and Scaling for OPC UA Adapter

Implement transformation and scaling for OPC UA adaptor the way it exists for PI OPC DA interface tags. The user can modify egressed tags and the data will be transformed / scaled when egressed.
Guest over 2 years ago in AVEVA™ Adapters 2 Future consideration

Classic Mode for Adapters

One of the big issues we have with adapters (outside of the lack of write capability) is not having the same control over creating and editing tags that we have with PI interfaces. As we talked about the adapter automatically creates PI tags or us...
Guest almost 2 years ago in AVEVA™ Adapters / General 5 Future consideration

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Guest over 1 year ago in AVEVA™ Adapters / General 1 No status

View PI Adapter log files via REST calls

We would like to be able to see the adapter log files via REST calls. Going to the machine itself to view is problematic because of remoting into the router and then going into the container to view. I think in a lot of containerized situations a ...
Guest over 2 years ago in AVEVA™ Adapters / General 3 Tell us more

Defining "Scan Class" and "Poll" Capabilities in Aveva Adapter for Azure Event Hubs

Define the "Scan Class" and "Poll" capabilities in the Aveva Adapter for Azure Event Hubs, similar to the functionality available in the Interface. Ensure the ability to manually select a "Scan Class" for PI Points and define it as "Poll".
Guest 4 months ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

PI Adapter for MQTT should include MQTT broker

Having to deal with a MQTT broker between the data source and the PI Adapter adds a single point of failure to the data handling and weakens the data flow end-to-end. From the data source we can guarantee that the data will reach the MQTT broker, ...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 4 In development