Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 597

Asset Summary Reporting

Generate an asset summary report on a periodic basis to summarize performance and other information.
Guest over 2 years ago in Visualization 1 No status

Hierarchical Navigation of Sites & Assets

Ability to setup a view of assets and asset relationships that enables a user to drill down into visual displays/dashboards/data for specific assets. For example: Customer --> Site --> Asset --> Visual --> Multiple Measurements Being...
Guest over 2 years ago in Visualization 0 No status

OCS Trends Configuration Needs to be Saved in Cloud - Not The Browser!!!

Currently, the trend configuration information is stored locally on the browser using cookies and does not persist between different computers. When local storage is refreshed or deleted, the trends then need to be reconfigured. Also, jumping betw...
Guest over 2 years ago in Visualization / Trend 0 No status

Include information from Json body in the stream name created by the MQTT Adapter

As a system admin I would like to send mqtt messages from multiple devices to a single topic on an mqtt broker. Each message would contain data for the device along with a field to say which device the data has come from. Then I would like to use ...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Specific debug log levels to troubleshoot specific issues

Similar to PI Interfaces (/DB for opcint), adapters should allow setting some additional debugging to troubleshoot specific issues, instead of only allowing a general LogLevel (Information, Trace, Warning, etc.) This would allow for more granular ...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Already exists

Can we please have an Adapter for the good old OPC DA, please ?

We still have OPC DA all over and it will take time for users to move over to UA Architecture unless one uses a wrapper or something to expose DA as UA (not sure if such a wrapper is available but other way is available). It would be great to have...
Guest over 2 years ago in AVEVA™ Adapters / New Connectivity 2 Declined

PI Adapter for Structured Data Files support for UoMs

No description provided
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files / General 6 Tell us more

OMF sample in node-red

I would like a sample that shows creating OMF data in Node-RED
Guest over 2 years ago in Developer Resources / Sample Requests 0 No status

Split up installation and infrastructure of Deployment Samples

We have installed the OSI PI System without problem with the scripts provided in these samples. But now it's only possible to run the full script with the installation/configuration of the infrastructure included. Is it maybe possible to split up ...
Guest over 2 years ago in Developer Resources / PI System Deployment Samples 1 No status

Clearly state that a Data message cannot include both a container ID and a type ID

Right now, the documentation: https://omf-docs.readthedocs.io/en/v1.0/Data_Messages.html Mentions that "For each object, either typeid or containerid must be specified". However, it does not clearly state that you CANNOT include both in a data m...
Guest over 2 years ago in Developer Resources / Open Message Format (OMF) 0 No status