Skip to Main Content
AVEVA™ Data Hub Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA Data Hub. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 546 of 546

Enable TLS Configuration

As a customer I want HTTP and HTTPS support for Edge DS so that I can configure the appropriate level of transport security for my deployment
Guest over 1 year ago in Edge Data Store / General 1 Declined

Store Images & Pictures into EDS

Ability to store images as time bound data into EDS, and send the images to OCS for longer term storage, viewing or modeling/analysis. Example scenario: a thermal camera takes a picture of a furnace, image stored locally, and then sent to OCS whe...
Guest over 1 year ago in Edge Data Store / Historian 2 Evaluating

Configure PI to OCS data transfer parameters

As of this writing, the PI to OCS Agent sends data every 30 seconds or every 10,000 events and this is currently not configurable. The idea is to allow an administrator to configure these types of parameters so they could control how often data is...
Guest over 1 year ago in PI to Data Hub 0 No Status

PI to OCS - AF Lookup Table Support

Support AF lookup table information on PI to OCS.
Guest over 1 year ago in PI to Data Hub 0 No Status

Add another Archive Mode option for the PI Interface for UFL

There should be a way to configure the PI UFL interface to both discard duplicate events (same value at the same timestamp) and record multiple unique values for the same timestamp when these events come from multiple data files. For example, if...
Guest over 1 year ago in PI Adapters / General 0 Tell us more

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Guest 2 months ago in PI Adapters / AVEVA Adapter for BACnet 0 No Status

Backfill/republish data from select streams used in the PI to ADH transfer

I would like the ability to resync data between my PI Data Archive and AVEVA Data Hub for select streams to easily recover any discrepancies.
Guest 4 months ago in PI to Data Hub / General 0 No Status

Allow selective AF Database indexing

The PItoDatahub agent will index the whole AF server. On big ones, this is tedious (one took more than 12 hours) - would prefer to have the ability to choose either on the agent or from ADH which AF databases to index.
Rene Thomassen about 1 year ago in PI to Data Hub / General 1 No Status

Failover support for Adapter for Modbus TCP

This is a new idea for the failover functionality specific to the Adapter for Modbus TCP. Copied from the original idea (https://pisystem.feedback.aveva.com/ideas/PIADAPTERS-I-23): As a customer, I need to ensure that the primary instance of the a...
Jiyeon Hwang about 1 year ago in PI Adapters / AVEVA Adapter for Modbus TCP 1 Planned

Provide additional features to support debugging

When first setting up the agent, there can be scenarios where there a number of errors to work through - for example tag not found. Summarization of errors and an alternative to event viewer would aid debugging.