To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 123 of 693

Provide a streamlined way to rename streams and push the changes to the endpoint

The current process forces the user to modify the adapter configuration (DataSource for the prefix, DataSelection for the stream name) and the endpoint (PIDA, OCS). The adapter should support modifying directly the stream name and push those chang...
Guest about 3 years ago in AVEVA™ Adapters / General 1 Future consideration

A Bulk Call for Last Values

A customer asks for a way to retrieve the last values of a group of streams in a single call.
Victor Zhang about 2 years ago in Developer Resources / AVEVA™ Data Hub API 0 No status

displayname/localname for identifier that excludes namespace and data type

Example: OPC UA Server 'Name': 2.0:W-HVAC-AC-1-IO!Wtot Namespace: 2 Datatype: 0 Identifier: W-HVAC-AC-1-IO!Wtot OPC UA Server 'DisplayName': W-HVAC-AC-1-IO!Wtot OPC UA Adapter {Identifier} returns: 2.0:W-HVAC-AC-1-IO!Wtot Required stream name: W-H...
Glenn Moffett over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Enable Adapter for OPC UA to use the Pub/Sub method

Pub/Sub is proposed to be a more efficient and scalable method of transferring data using OPC UA. Allowing the adapter to access data in this way would increase the options for data collection, and allow the OPC UA adapter to be used in many more ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Support System States for the Adapter for Azure Event Hubs

The data passed through the Adapter for Azure Event Hubs can be very dynamic in its configuration. It would be useful to be able to send system states to indicate bad data, and possibly the nature of that bad data. In the same way that interfaces ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 2 No status

More control on MQTT parameters on the AVEVA Adapter for MQTT

It would be nice to have more control on additional MQTT parameters for the AVEVA Adapter for MQTT. We are especially interested in having control on the QoS of the subscription. Setting this would give us more control in buffering, especially whe...
Guest 11 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

PI Adapter for GE e-terrahabitat/HabConnect

We need a new robust product to support data transfer between GE e-terrahabitat/HabConnect and PI. This product would need to support the following: Highly available remote management/deployment multiple instances on a single node (to support larg...
Guest over 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Streaming API - for real time visualization

As a OCS real-time-visualization-client I require a Streaming API so that I can avoid continuously polling the REST API. Similar to the WSS Chanels in PI WebAPI Or something like PI WebAPI Stream Updates could also work
Guest about 3 years ago in Developer Resources / AVEVA™ Data Hub API 1 No status

Expose REST API for PI to OCS configuration

Provide a documented REST API for PI to OCS connection and data transfer configuration. This would enable scripting against these configurations, allowing users to update their data transfers automatically, and manage them in a customer-specific way.
Guest about 3 years ago in Developer Resources / AVEVA™ Data Hub API 0 No status

PI Interface DNP3 - unsolicited data listen only mode of operation requested

Is there an option in DNP3 driver (In fact at TCP level) to make it listen on a certain (usually 20000 for DNP3)? In era of IoT devices, most devices are sleeping devices, they wake up usually once a day and push data to DNP3 Master (PI), however ...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 1 Tell us more