Skip to Main Content
CONNECT feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Change schema name when publishing Virtual Tables to Databricks

Virtual Tables exposed to Databricks appear in Databricks using a unique ID as schema name, which is very cumbersome to use. It would be helpful to have the ability to specify the schema name
Roberto Serrano 8 months ago in Data Platform Integration / Virtual Tables & Shares 1 No status

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Planned

Add a parameter to disable NTLM authentication

On the "Health endpoints parameters" page of the documentation of any AVEVA Adapter, it states that Negotiate (i.e. try Kerberos first and fall back to NTLM if that fails) will be used if a username/password pair and a clientId/clientSecret pair a...
Guest about 1 month ago in AVEVA™ Adapters / General 0 No status

Adapter for BACnet - defaultStreamIdPattern add ObjectName as possible parameter

Currently, for the Adapter for BACnet its [Data source parameters] defaultStreamIdPattern does not have an option to include the ObjectName in the defaultStreamIdPattern. It would be good to include this as a possible parameter for the defaultStre...
Guest 4 months ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Enable OmfEgress component to be configurable by instance (by component)

In our process we wish to send a different set of data to different PI environments. For instance we would like all data to egress to the PROD environment while only egress a subset of data to the DEV environment, in which we don't need all the da...
Guest about 4 years ago in AVEVA™ Adapters / General 7 Future consideration

Send only data that has changed.

When transferring data via satellite it is necessary to keep bandwidth usage to a bare minimum. Currently OMF must send all values regardless of whether they have changed or not. If it could send only the data parameters that have changed that wou...
Guest about 4 years ago in Developer Resources / Open Message Format (OMF) 6 Declined

Allow client-level failover on a per data source component level

Currently the client-level failover for Adapters occur on a per Adapter level. Which means that for instances where multiple data sources are configured, in some circumstances failover may result in an instance with a bad connection to a particula...
Guest over 1 year ago in AVEVA™ Adapters / General 1 No status

Allow Definition of Point Attributes via OMF to PI Web API

When creating containers via OMF the PI Points are created with default Point Attributes - if these need to be changed it is a manual process to subsequently change the attributes appropriately. As OMF solutions can be easily deployed it would be ...
Guest about 4 years ago in Developer Resources / Open Message Format (OMF) 2 No status

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Increased Editability of Virtual Table Fields

Currently, the only editable field in the Virtual Table settings is the Refresh Interval because modifying other fields render the table invalid, and require re-initialization or rebuilding. Other fields like Retrieval Mode, Retrieval Interval, an...
Dennica Mitev 5 months ago in Data Platform Integration / Virtual Tables & Shares 0 No status