Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 88 of 693

Data Retention configuration for EDS SDS

We have no information regarding data retention. This could be clarified. Data retention should be better configurable as of now, only the stream size can be configured just by estimation. Provide a sizing and calculation tool for Edge Data Store ...
Hans-Otto Weinhold over 1 year ago in AVEVA™ Edge Data Store / Historian 0 No status

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Edge Data Store / Ingress 0 Planned

EDS: Modbus Serial Connector

Ability for Modbus Serial connector to write data to Edge Data Store.
Guest about 3 years ago in AVEVA™ Edge Data Store / Ingress 1 Declined

Event-based total (non-weighted Total) Summary Type

As a Data View creator, I want an event based total Summary Type data field so that I can see a calculated sum of values that is not weighted by time (or any index)
Guest about 3 years ago in Data Views 0 No status

Add an Aligned data retrieval mode for data views

It would be beneficial to have a data retrieval mode that creates one row per recorded value for one property, and interpolates values at those timestamps for the rest of the properties. This is a hybrid of interpolated and stored, where a single ...
Guest about 3 years ago in Data Views 0 No status

Temporarily Share Data

As a company that shares data with partners, we need to share data temporarily (has an expiration) SO THAT my partner can see the data they need right now when they need it but they don't have access to it for ever.
Guest about 3 years ago in Community Data Sharing / General 0 No status

Cross Account/Tenant Data Writing Through Community

Ability to write data into another account via Communities (data sharing). For example, one service provider reads data from their customer, uses models and machine learning to generate results that get written back into the customer's Account.
Guest about 3 years ago in Community Data Sharing / General 0 No status

Allow Assets to Reference Community Streams

Allow for assets to reference community streams so that community data sharing can be used in the same manner as other OCS streams. These assets should be kept private from the community, but simply reference streams shared with the community.
Guest about 3 years ago in Community Data Sharing / General 0 No status

Provide possibility to filter streams in a REST API call based on their origin

Challenge: A customer (industrial operator) is sharing data with an equipment vendor on a specific equipment through AVEVA Data Hub Communities. The equipment vendor reads data via REST API using a (python) script to process it for further data an...
Guest over 2 years ago in Community Data Sharing / General 0 No status

Do not bundle PI Adapters with EDS

Reduce the footprint of EDS by not bundling adapters with EDS but instead have them be a separate installation so only the desired adapters end up being installed on the device. It will also allow easier for a clearer process when an adapter needs...
Guest about 3 years ago in AVEVA™ Edge Data Store / Installation 1 Future consideration