Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 57 of 696

EDS: security/authentication mechanism

Customer wants to deploy EDS at machine level to collect data from PLCs which are directly connected to the machine which would imply a proper security / authentication mechanism for EDS
Guest about 3 years ago in AVEVA™ Edge Data Store / General 1 Tell us more

Clearly state that a Data message cannot include both a container ID and a type ID

Right now, the documentation: https://omf-docs.readthedocs.io/en/v1.0/Data_Messages.html Mentions that "For each object, either typeid or containerid must be specified". However, it does not clearly state that you CANNOT include both in a data m...
Guest about 3 years ago in Developer Resources / Open Message Format (OMF) 0 No status

Data Retention configuration for EDS SDS

We have no information regarding data retention. This could be clarified. Data retention should be better configurable as of now, only the stream size can be configured just by estimation. Provide a sizing and calculation tool for Edge Data Store ...
Hans-Otto Weinhold almost 2 years ago in AVEVA™ Edge Data Store / Historian 0 No status

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Edge Data Store / Ingress 0 Planned

EDS: Modbus Serial Connector

Ability for Modbus Serial connector to write data to Edge Data Store.
Guest about 3 years ago in AVEVA™ Edge Data Store / Ingress 1 Declined

OMF: Container-level overrides

Ability to override Type-level property keywords on a Container level.
Guest about 3 years ago in Developer Resources / Open Message Format (OMF) 0 Planned

Ability to get list of point sources from PI Web API

Currently it's not possible to get a list of point sources from the PI Web API. Within PI SMT it is possible to view tag counts by point source, but this feature is not available to be accessed programprogrammaticallyatically.
Guest almost 3 years ago in Developer Resources / General 0 No status

Do not bundle PI Adapters with EDS

Reduce the footprint of EDS by not bundling adapters with EDS but instead have them be a separate installation so only the desired adapters end up being installed on the device. It will also allow easier for a clearer process when an adapter needs...
Guest about 3 years ago in AVEVA™ Edge Data Store / Installation 1 Future consideration

Deliver Data to Customers via Custom Portal

As a service provider, I need to incorporate data into our multi-tenant customer portal (custom) SO THAT we can share data and other information with our customers.
Guest about 3 years ago in Developer Resources / General 0 No status

OMF: Per-object CRUD operation override

Add the ability to override the message-level CRUD mode for each object (Type, Container, or Data) within the body.
Guest about 3 years ago in Developer Resources / Open Message Format (OMF) 0 Declined