To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 21 of 693

Support time series analysis in thread logic block

When doing time series analysis, right now there is no possiblity to let the thread look for a previous or next event (like in PI PE syntax). This makes time series analysis more challenging as one has to define a specific time range and look with...
Hans-Otto Weinhold 4 months ago in AVEVA™ Advanced Analytics 0 Needs review

Better Preview possibilites of Thread reload

When creating a thread logic, right now there is no backfilling preview feature available which would allow to get a preview on an event creation logic within a logic block or when doing a calculation. It would be good to have a similar preview fe...
Hans-Otto Weinhold 4 months ago in AVEVA™ Advanced Analytics 0 Needs review

IntelliSense support for thread logic block

Prompt for correct syntax and general aid to writing logic.
Glenn Moffett 10 months ago in AVEVA™ Advanced Analytics 0 Needs review

Auto-sync objects from Data Services

Data services is the system of record and customer would like to see Advanced Analytics reflect the current state of objects (asset, streams, metadata) in Data Servies
Glenn Moffett 10 months ago in AVEVA™ Advanced Analytics 0 Needs review

More control on MQTT parameters on the AVEVA Adapter for MQTT

It would be nice to have more control on additional MQTT parameters for the AVEVA Adapter for MQTT. We are especially interested in having control on the QoS of the subscription. Setting this would give us more control in buffering, especially whe...
Guest 11 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Allow MQTT adapter to parse timestamps in local time without specifying a timezone suffix to each timestamp

We would like the MQTT Adapter to be able to interpret timestamps in local time without needing to explicitly state the timezone or UTC offset in each timestamp, but for the adapter to always interpret the timestamps as being in a specific timezon...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Expose AVEVA Advanced Analytics outputs to Data Hub - e.g. recommendations

the key output from AAA is often not just the anomaly score. More interesting will be things like ideal running conditions, ideal model conditions.
Rene Thomassen over 1 year ago in AVEVA™ Advanced Analytics 0 Needs review

Include information from Json body in the stream name created by the MQTT Adapter

As a system admin I would like to send mqtt messages from multiple devices to a single topic on an mqtt broker. Each message would contain data for the device along with a field to say which device the data has come from. Then I would like to use ...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Allow PI Adapter for MQTT to log the raw json payload received from the broker

For troubleshooting, it can be very helpful to see the raw json payload that the adapter has received from the broker, rather than just the error response from the attempted parsing. It can be difficult to know why a parsing attempt has failed wit...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 2 Future consideration

Allowing the MQTT adapter to set PI Point attributes during the creation process

we're interested in having the ability to configure the zero, span and some other points parameters during the creation of the PI points. currently when points are created. they're defaulting to zero=0 and span=100. while also displaying Boolean p...