To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 49 of 694

Pro-active notification if data collection stops

Challenge: In normal operation, there is no need to constantly check, if data collection is up and running and healthy. In some cases, data collection can stop for any particular reason, but there is right now no possibility to see this or receive...
Jeff Branfield about 2 years ago in Software Management / Edge System Health & Status 0 No status

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

support multiple assets with one AssetSupportedType reference

Simplify configuration, one API call instead of multiple for a set of assets.
Glenn Moffett about 1 year ago in Events 0 Needs review

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

Add Counts to AVEVA Data Hub Edge Data Store & Adapters Status Display

Add count next to each of the status (filter) boxes and enable status sorting based on the count. This will enable an admin to get a general overview of the health of the EDS and adapter population
Brian Deslatte over 1 year ago in Software Management / Edge System Health & Status 0 No status

OCS to IP.21 Data Egress

Ability to egress OCS data to an on prem IP.21 system for the purposes of ensuring operators on the plant floor can visualize this data with their existing displays for real time decision making.
Guest about 3 years ago in General / Data Egress 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Accept HEX numbers for Register offsets in data selection

Most modbus equipment providers provide information using registers in Hex format i.e. 0x0000 ~ 0xFFFF. It would be nice if the offset could accept this to avoid error in conversions HEX to DEC. Would make things alot more seamless/easier.
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration