To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 29 of 694

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Time based summary calculations

Ability to perform hourly, daily, weekly monthly, quarterly aggregation summary calculations on data. Often useful for utility consumption KPIs / metrics.
Guest about 3 years ago in General / Calculations 1 No status

Apply configuration remotely from AVEVA Data Hub

Remote configuration of Edge system software (Edge Data Store (EDS) and PI Adapters) from AVEVA Data Hub. The ability to apply configuration and make configuration updates remotely from AVEVA Data Hub. Note: This request is specific to applying co...
Ryan McErlean about 3 years ago in Software Management 0 No status

Pro-active notification if data collection stops

Challenge: In normal operation, there is no need to constantly check, if data collection is up and running and healthy. In some cases, data collection can stop for any particular reason, but there is right now no possibility to see this or receive...
Jeff Branfield about 2 years ago in Software Management / Edge System Health & Status 0 No status

Performance Equation capability in Data Hub

When AVEVA products such as AVEVA Production Accounting use the performance equation capabilities of on-premise PI Server extensively, but when the same product tries to consume the data from the Data Hub for similar complex calculations or valida...
Jaibabu Yakkala over 2 years ago in General / Calculations 0 No status

Make a BACnet/SC adapter

BACnet/SC is essentially the same as BACnet/IP... but secures the communication
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 1 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

Add Counts to AVEVA Data Hub Edge Data Store & Adapters Status Display

Add count next to each of the status (filter) boxes and enable status sorting based on the count. This will enable an admin to get a general overview of the health of the EDS and adapter population
Brian Deslatte over 1 year ago in Software Management / Edge System Health & Status 0 No status

Reference Manual in Python Client: adh_sample_library_preview

Currently, adh_sample_library_preview is only avaiable in Github Example code. https://github.com/AVEVA/sample-adh-data_views-python/blob/main/program.py However, it is not helpuful for users. It is better to setup "Reference Manual" of adh_sample...
Satoru Arakawa over 1 year ago in General / Help / Documentation / Videos 0 No status

Calc Scheduling: Wait for Data

The ability to say wait until I have all the data for my calculation inputs for situations where the data comes in more slowly. I need more flexibility in the scheduling of calcs.