To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 141 of 693

CONNECT Agent for AVEVA Plant SCADA (Citect)

AVEVA Plant SCADA 2020r2 and newer, has an OPC UA Server, so the AVEVA Adaptor for OPC UA can be used to send data to CONNECT data services (AVEVA Data Hub). However native connectivity like the PI-to-CONNECT Agent or the System Platform Connector...
John Marriott over 1 year ago in AVEVA™ Adapters / New Connectivity 0 No status

ADH to store Enumeration Sets

We make use of Enumeration Sets in AF to associate labels to Integer values. We need the same representation in ADH.
Christian Leroux about 3 years ago in Data Management & Storage / Sequential Data Store (SDS) 0 No status

Importing KML file Mapping Information

I have a KML file that has mapping information for my location it would be nice to be able to import this file and use it within the OCS platform. Keyhole Markup Language (KML) is an XML notation for expressing geographic annotation and visualiza...
Guest about 3 years ago in Data Management & Storage / Sequential Data Store (SDS) 0 No status

Easier Experience for Editing Stream Types

Stream Types are not editable in OCS SDS by design but it's painful to have to recreate a new type and do your work all over again when you need to make a change or forgot something. Please capture related scenarios you have around making change...
Guest about 3 years ago in Data Management & Storage / Sequential Data Store (SDS) 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

If data contains asset information, this data shall be written to asset related streams

Challenge: We have (CSV) data files which come from Laboratory or other measuring equipment where the data lines contain information on which asset the measurement was taken from. In our particular use case, we read sample data from lab analyzer w...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

PI Adapter for Structured Files - User friendly interface

Make the configuration experience more user friendly. Add a user interface for adapter configuration and management.Today, this adapter is too configuration intensive