To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 35 of 694

Built-in weather data adapter

During a Lighthouse project a customer noted that it would be nice if ADH provided a built-in ‘weather data adapter’. This adapter would be part of the SaaS offering and when enabled, would consume weather data from a trusted source into ADH Streams
Guest almost 2 years ago in Data Platform Integration / New Integrations 0 No status

Integrate ML Models back to Remote Edge Systems

The ability to push Machine Learning models trained from data in the cloud environment back down to remote assets / Edge systems.
Guest about 3 years ago in Data Platform Integration / New Integrations 0 No status

Events duration column should be a timespan rather than a decimal

When viewing events in AVEVA Advanced Analytics, the duration column shows the event duration as a decimal value representing the number of hours the event was open. For example, a duration of 0.1 = 6 minutes. This is not immediately intuitive, an...
Adam Fink 11 months ago in AVEVA™ Advanced Analytics 0 Needs review

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Edge Data Store / Ingress 0 Planned

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

EDS: Modbus Serial Connector

Ability for Modbus Serial connector to write data to Edge Data Store.
Guest about 3 years ago in AVEVA™ Edge Data Store / Ingress 1 Declined

Trendminer Integration with CONNECT

Integrate Trendminer with CONNECT so customers can use both applications in a SaaS environment.
Guest about 3 years ago in Data Platform Integration / New Integrations 0 No status

Pro-active notification if data collection stops

Challenge: In normal operation, there is no need to constantly check, if data collection is up and running and healthy. In some cases, data collection can stop for any particular reason, but there is right now no possibility to see this or receive...
Jeff Branfield about 2 years ago in Software Management / Edge System Health & Status 0 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration