Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 588

Allow client-level failover on a per data source component level

Currently the client-level failover for Adapters occur on a per Adapter level. Which means that for instances where multiple data sources are configured, in some circumstances failover may result in an instance with a bad connection to a particula...
Guest 12 months ago in AVEVA™ Adapters / General 0 No status

PI to CONNECT should have a verification tool to make sure there are no gaps in the data

When using PI to CONNECT there might be errors in the transfer due to disconnections or other network issues. Ideally PI to CONNECT would have a tool to verify if the data was properly transferred by checking the data.
Fabio Dani 8 months ago in PI to CONNECT / General 0 No status

ADH Configurable Calculations

Ability to configure calculations based on ADH data and store the values back into ADH as new Streams / Asset References.
Guest over 3 years ago in General / Calculations 1 No status

Better Data Hub API time zone support

AVEVA Data Hub APIs need to provide better support for viewing data in different time zones / my local timezone. We should be able to encode UTC UTC+13 when making queries to the system.
Guest over 3 years ago in Developer Resources / CONNECT data services API 0 No status

Notifications Support from Cloud Services

I need to be able to be notified when something important happens in the process/assets we are working with SO THAT I can take action on the issue.
Guest over 3 years ago in General 2 No status

Support outputs/write data from PI Adapters

No description provided
Guest over 3 years ago in AVEVA™ Adapters / General 4 No status

Root Element should be added to the transfer

When we create a transfer from PI AF there is a way to select a Root Element to start the search. However the root element from where we start the search is not added to the transfer. Ideally we would be able to add the root element into the trans...
Fabio Dani 3 months ago in PI to CONNECT / General 0 No status

Sampling/Publishing Interval parameters to be part of Data Selection description

When configuring the AVEVA Adapters in general, we would find more convenient to be able to define the ‘Sampling Interval’ and 'Publishing Interval' parameters inside the ‘Data Selection’ configuration per each data stream. For instance, when desc...
Christian Leroux almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Add ability to uncheck or remove attributes from existing transfer

Transfers are initially added by searching and then selecting elements then attributes to add. When we want to edit the transfer, we are only able to remove entire elements, not by attributes. This became an issue when we later found that we had a...
Hege Dammen about 1 year ago in PI to CONNECT / General 0 No status