To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 6

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Guest 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 Planned

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 14 Planned

OMF: Ability to patch data messages

Add the ability to provide partial information for an existing data point. This is meant as a partial update which replaces values for some properties of a type without affecting others.
Guest about 3 years ago in Developer Resources / Open Message Format (OMF) 0 Planned

Failover support for Adapter for DNP3

This is a new idea for the failover functionality specific to the Adapter for DNP3. Copied from the original idea (https://pisystem.feedback.aveva.com/ideas/PIADAPTERS-I-23): As a customer, I need to ensure that the primary instance of the adapter...
Jiyeon Hwang over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 0 Planned

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Edge Data Store / Ingress 0 Planned

OMF: Container-level overrides

Ability to override Type-level property keywords on a Container level.