Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 726

Tableau Integration

Tighter product integration between Tableau and CONNECT data services. Note that CONNECT's APIs and data views can likely be used today to get data from Cds into Tableau.
Todd Brown 9 months ago in Data Platform Integration / New Integrations 1 No status

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Guest 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Allow partitioning configuration for virtual tables

Databricks allows for specification of partitioning configuration on a deltatable. In some cases, this can improve query performance when querying the deltashare. It would be nice if on the virtual table, partitioning options were available which ...
Adam Fink 2 months ago in Data Platform Integration / Virtual Tables & Shares 0 No status

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Guest 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

The DNP3 Adapter should support group 40

The interface supports this group. The Adapter does not (see https://docs.aveva.com/bundle/adapter-for-dnp3/page/1231146.html). It is essential that the Adapter have this identical feature as the interface, to allow it to read the same data and be...
Daniel Lopez 2 months ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 0 No status

Provide synced times for Manual Refresh of with Scheduled Refresh of virtual tables with Interpolated Mode

When one does a manual refresh of a virtual table that is set for interpolated data, no cues are given of the offset \ start index. As a consequence, if the user picks a start time or end time that is inconsistent with scheduled refresh start inde...
Brian Deslatte about 1 month ago in Data Platform Integration / Virtual Tables & Shares 0 No status

Support security baselining

As a PI administrator, I need to baseline the security configuration of my PI System to ensure OSIsoft security best practices are followed. Below is a list of requested features. Baseline verification (read-only) for PI Data Archive: - PI Data ...
Guest over 3 years ago in Developer Resources / PI System Deployment Tests 2 No status

Allow PI Adapter for MQTT (Generic) to process non-json payloads

Some MQTT devices do not send json payloads; for example, some devices send a single value as the payload for a specific topic. It would be beneficial for the adapter to be able to handle this rather than to convert these payloads into json befo...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 3 In development

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Guest 5 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Adapter should have the ability to read from a TCP Socket

In a lighthouse project we needed to read from a TCP Socket. Ideally the Adapter for Structured Data files would be able to read from a socket and process its data.
Fabio Dani 3 months ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 1 No status