To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA Data Hub. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

PI Adapters

Showing 52

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani 11 months ago in PI Adapters / AVEVA Adapter for OPC UA 0 No Status

REST API data source

e.g.: weather forecast, 3rd party
Glenn Moffett over 1 year ago in PI Adapters / New Connectivity 0 No Status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest 3 months ago in PI Adapters / AVEVA Adapter for Azure Event Hubs 0 No Status

Allow restricting access to the Adapter to only allow configuration by specific users

We want to make sure that we have more control over who can update an Adapter. Is there a way to add a login or other restriction to only permit certain users to be able to modify Adapters, similar to how, with PI Connectors, only specific Windows...
Daniel Lopez 6 months ago in PI Adapters / General 1 No Status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest 3 months ago in PI Adapters / AVEVA Adapter for Modbus TCP 0 No Status

Permit non-protected references

The secrets references is a very useful addition but they are only permitted for "protected" parameters. It would be useful to also create references for non-protected parameters. Using references for non-protected parameters would help with creat...
Mike Horrocks 10 months ago in PI Adapters / General 0 No Status

Allow MQTT adapter to parse timestamps in local time without specifying a timezone suffix to each timestamp

We would like the MQTT Adapter to be able to interpret timestamps in local time without needing to explicitly state the timezone or UTC offset in each timestamp, but for the adapter to always interpret the timestamps as being in a specific timezon...
Guest over 1 year ago in PI Adapters / AVEVA Adapter for MQTT 0 No Status

PI Adapter for Apache Kafka

Create a PI Adapter that supports reading data from Apache Kafka. Please comment with any specific data, requirements, or use cases that this adapter would need to support!
Guest over 1 year ago in PI Adapters / New Connectivity 0 No Status

Allow default settings (eg. disable compression) for tags created by Adapters

We would like to be able to specify default settings for tags created by the adapters. This would include things such as disabling compression for tags on this adapter (without disabling it as the default for all new tags on the Data Archive). Thi...
Guest over 1 year ago in PI Adapters / General 0 No Status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold 8 months ago in PI Adapters / AVEVA Adapter for Modbus TCP 0 No Status