Skip to Main Content
Data services feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT data services. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 720 of 720

PI Adapter for OPC UA should poll a series of items based on a trigger events

Same as the PI Interface for OPC DA feature with "Trigger Tags", the idea is to poll for updates on a series of item streams (tags) only when a certain item stream updates. The benefit of this is to create timestamp alignments between a series of...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Guest 4 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Guest 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

PI to Connect agent needs to be collective aware

The PI to Connect agent is not collective aware. Instead, only a single archive can be mapped to the agent. Please allow the PI to Connect agent to utilize collectives. This increases the system's overall resiliency.
Guest over 3 years ago in PI to CONNECT / General 2 In development

Include the "Include variables having historical data only" flag for the OPC UA Adapter

The OPC UA Connector has a feature that should also be included with the AVEVA Adapter for OPC UA : UserAccessLevel=HistoryRead - No real time data to subscribe for and only has historical data stored Please add this feature to the adapter.
Guest 2 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

PI to CONNECT should have a verification tool to make sure there are no gaps in the data

When using PI to CONNECT there might be errors in the transfer due to disconnections or other network issues. Ideally PI to CONNECT would have a tool to verify if the data was properly transferred by checking the data.
Fabio Dani 5 months ago in PI to CONNECT / General 0 No status

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Guest 5 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Search Panel should be expandable

Stream names are often long and the current space that we have to display the streams is very limited making it difficult to find the streams we are interested in.
Fabio Dani 3 months ago in CONNECT to PI 0 No status

Allow Transfer Edit

The current version of the Transfer does not allow edits. This makes things difficult when project evolves and more streams need to be added to the transfer.
Fabio Dani 3 months ago in CONNECT to PI 0 No status

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 15 Planned